MedElevator Войти в исследования
← Поиск публикаций
European heart journal. Cardiovascular Imaging · 2015

Left atrial booster pump function is an independent predictor of subsequent life-threatening ventricular arrhythmias in non-ischaemic cardiomyopathy.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Negishi Kazuaki, Negishi Tomoko, Zardkoohi Omeed, Ching Elizabeth A, Basu Nivedita, Wilkoff Bruce L, Popović Zoran B, Marwick Thomas H

Аннотация

AIMS: Left atrial (LA) function helps to preserve cardiac output and to control pulmonary capillary wedge pressure in the setting of left ventricular (LV) impairment, but little is known about the contribution of the LA function to ventricular arrhythmia. We sought whether LA booster pump function was associated with arrhythmias in patients undergoing primary prevention implantable cardioverter-defibrillator (ICD) implantation for non-ischaemic dilated cardiomyopathy (NICM), independent of global longitudinal strain (GLS) and mechanical dispersion (MD).

METHODS AND RESULTS: We identified 124 NICM patients (56 ± 13, 67 male) who underwent echocardiography pre-ICD implantation for primary prevention. The main outcome measure was appropriate ICD therapy (anti-tachycardia pacing or shock). The mitral A-wave was used as an LA functional marker. MD was defined as standard deviation of time to peak strain of each segment. Over a median follow-up of 3.8 ± 2.2 years, 36 patients had appropriate ICD therapy, including 23 shocks. Patients with appropriate ICD therapy had lower A-wave velocity (P < 0.001), larger LA volume (P < 0.001), and impaired circumferential MD (P = 0.006), but similar ejection fraction (EF) (P = 0.40) and GLS (P = 0.11). In sequential Cox proportional hazards models, A-wave, E/A ratio, and GLS were significantly associated with outcomes, independent of age, sex, and cardiac resynchronization therapy defibrillator or left bundle branch block. In nested Cox models, mitral A-wave had a prognostic value incremental to models with LV systolic (EF and GLS) and diastolic functional parameters (E/A, E/e', and LA volume) and MD.

CONCLUSION: LA booster pump function was an independent and incremental predictor of arrhythmias in NICM over GLS and MD, and may aid better risk stratification in this population.

Предметные рубрики MeSH