Can Deep Learning-Based Auto-Contouring Software Achieve Accurate Pelvic Volume Delineation in Volumetric Image-Guided Radiotherapy for Prostate Cancer? A Preliminary Multicentric Analysis.

Grossi Cristiano, Munoz Fernando, Bonavero Ilaria, Ngassam Eulalie Joelle Tondji, Garibaldi Elisabetta, Airaldi Claudia, Celia Elena, Nassisi Daniela, Brignoli Andrea, Trino Elisabetta, Bianco Lavinia, Leardi Silvia, Bongiovanni Diego, Valero Chiara, Redda Maria Grazia Ruo

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Radiotherapy (RT) is a mainstay treatment for prostate cancer (PC). Accurate delineation of organs at risk (OARs) is crucial for optimizing the therapeutic window by minimizing side effects. Manual segmentation is time-consuming and prone to inter-operator variability. This study investigates the performance of Limbus® Contour® (LC), a deep learning-based auto-contouring software, in delineating pelvic structures in PC patients.

METHODS

We evaluated LC's performance on key structures (bowel bag, bladder, rectum, sigmoid colon, and pelvic lymph nodes) in 52 patients. We compared auto-contoured structures with those manually delineated by radiation oncologists using different metrics.

RESULTS

LC achieved good agreement for the bladder (median Dice: 0.95) and rectum (median Dice: 0.83). However, limitations were observed for the bowel bag (median Dice: 0.64) and sigmoid colon (median Dice: 0.6), with inclusion of irrelevant structures. While the median Dice for pelvic lymph nodes was acceptable (0.73), the software lacked sub-regional differentiation, limiting its applicability in certain other oncologic settings.

CONCLUSIONS

LC shows promise for automating OAR delineation in prostate radiotherapy, particularly for the bladder and rectum. Improvements are needed for bowel bag, sigmoid colon, and lymph node sub-regionalization. Further validation with a broader and larger patient cohort is recommended to assess generalizability.

Для цитирования: Grossi Cristiano, Munoz Fernando, Bonavero Ilaria, Ngassam Eulalie Joelle Tondji, Garibaldi Elisabetta, Airaldi Claudia, Celia Elena, Nassisi Daniela, Brignoli Andrea, Trino Elisabetta, Bianco Lavinia, Leardi Silvia, Bongiovanni Diego, Valero Chiara, Redda Maria Grazia Ruo. Can Deep Learning-Based Auto-Contouring Software Achieve Accurate Pelvic Volume Delineation in Volumetric Image-Guided Radiotherapy for Prostate Cancer? A Preliminary Multicentric Analysis.. Current oncology (Toronto, Ont.). 2025. DOI: 10.3390/curroncol32060321.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.