Diagnostic Performance of Near-Infrared Fluorescent Marking Clips in Laparoscopic Gastrectomy.

Kumagai Koshi, Yoshida Masashi, Ishida Hiroki, Ishizuka Naoki, Ohashi Manabu, Makuuchi Rie, Hayami Masaru, Ida Satoshi, Yoshimizu Shoichi, Horiuchi Yusuke, Ishiyama Akiyoshi, Yoshio Toshiyuki, Hirasawa Toshiaki, Fujisaki Junko, Nunobe Souya

СтатьяКлиническое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Accurate tumor localization and resection margin acquisition are essential in gastric cancer surgery. Preoperative placement of marking clips in laparoscopic gastrectomy as well as intraoperative gastroscopy can be used for gastric cancer surgery. However, these procedures are not available at all institutions. We conducted a prospective clinical trial to investigate the diagnostic performance of near-infrared fluorescent clips (ZEOCLIP FS) in laparoscopic gastrectomy.

MATERIALS AND

METHODS

Patients with gastric cancer or neuroendocrine tumor in whom laparoscopic distal, pylorus-preserving, or proximal gastrectomy was planned were enrolled (n = 20) in this study. Fluorescent clips were placed proximal and/or distal to the tumor via gastroscopy on the day before surgery. During surgery, the clips were detected using a fluorescent laparoscope, and suturing was performed where fluorescence was detected. The clip locations were then confirmed via gastroscopy, and the stomach was transected. The primary endpoint was the detection rate of the marking clips using fluorescence, and the secondary endpoints were complications and distance between the clips and stitches.

RESULTS

Among the 20 patients enrolled, distal and pylorus-preserving gastrectomies were performed in 18 and 2 patients, respectively. All clips were detected in 15 patients, indicating a detection rate of 75.0% (90% confidence interval: 54.4%-89.6%). Furthermore, no complications related to the clips were observed. The median distance between the clips and stitches was 5 (range, 0-10) mm.

CONCLUSIONS

We report the feasibility and safety of preoperative placement and intraoperative detection of near-infrared fluorescent marking clips in laparoscopic gastrectomy.

Для цитирования: Kumagai Koshi, Yoshida Masashi, Ishida Hiroki, Ishizuka Naoki, Ohashi Manabu, Makuuchi Rie, Hayami Masaru, Ida Satoshi, Yoshimizu Shoichi, Horiuchi Yusuke, Ishiyama Akiyoshi, Yoshio Toshiyuki, Hirasawa Toshiaki, Fujisaki Junko, Nunobe Souya. Diagnostic Performance of Near-Infrared Fluorescent Marking Clips in Laparoscopic Gastrectomy.. The Journal of surgical research. 2024. DOI: 10.1016/j.jss.2024.05.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.