Journal of perinatology : official journal of the California Perinatal Association · 2024
Glottic opening detection using deep learning for neonatal intubation with video laryngoscopy.
СтатьяПоддержка NIH: внешняя программаНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Majeedi Abrar, Peebles Patrick J, Li Yin, McAdams Ryan M
Аннотация
OBJECTIVE: This study aimed to develop an artificial intelligence (AI) method to augment video laryngoscopy (VL) by automating the detection of the glottic opening in neonates, as a step toward future studies on improving intubation outcomes.
STUDY DESIGN: A deep learning model, YOLOv8, was trained on 1623 video frames from 84 neonatal intubations to detect the glottic opening and evaluated using 14-fold cross-validation on metrics like precision and recall. Additionally, it was compared with 25 medical providers of varied intubation experience to assess its relative performance.
RESULTS: The model demonstrated a precision of 80.8% and a recall of 75.3% in identifying the glottic opening, detecting it 0.31 s faster than the average medical provider. It performed comparably or better than novice and intermediate providers, and slightly slower than experts.
CONCLUSION: AI-powered tools can aid VL by providing real-time guidance, potentially enhancing neonatal intubation safety and efficiency for less experienced users.
STUDY DESIGN: A deep learning model, YOLOv8, was trained on 1623 video frames from 84 neonatal intubations to detect the glottic opening and evaluated using 14-fold cross-validation on metrics like precision and recall. Additionally, it was compared with 25 medical providers of varied intubation experience to assess its relative performance.
RESULTS: The model demonstrated a precision of 80.8% and a recall of 75.3% in identifying the glottic opening, detecting it 0.31 s faster than the average medical provider. It performed comparably or better than novice and intermediate providers, and slightly slower than experts.
CONCLUSION: AI-powered tools can aid VL by providing real-time guidance, potentially enhancing neonatal intubation safety and efficiency for less experienced users.