Multiple uterine perforations during manual vacuum aspiration: the need to increase the clinical awareness of attending healthcare professionals.
Аннотация
BACKGROUND
The risk of uterine perforation during manual vacuum aspiration (MVA) is reduced by using Karman cannula (which has a rounded tip) during the procedure.
METHODS
A 35-year-old multigravida at 13 gestational weeks presented with vaginal bleeding of a day duration and ultrasound evidence of retained products of conception suggestive of incomplete miscarriage. The patient was rhesus D positive and stable. She had MVA which was performed using Karman cannula, and developed severe vaginal bleeding. The differential diagnoses were incomplete uterine evacuation and uterine perforation.
RESULTS
During a laparotomy in Lloyd-Davies position, haemoperitoneum and six uterine perforations on the anterior and fundal parts, each approximately 5 mm in length (Figure 1), were found. The perforations were repaired and a check uterine curettage under oxytocic cover showed an empty uterus. The abdominal cavity was washed and closed. She was transfused three units of red blood cell concentrate and had a normal six weeks follow-up.
CONCLUSION
When an instrument inserted into the uterus is pushed beyond the estimated depth of the uterus, a perforation must be suspected and the condition may be managed conservatively. A surgical procedure complicated by surgeon's loss of perception (in this case tactile) of tissues' anatomy is hazardous.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.