Comparison of safety and effectiveness of micropulse transscleral cyclophotocoagulation and "slow cook" diode laser transscleral cyclophotocoagulation in patients with refractory open-angle glaucoma.

Russ Heloisa Helena Abil, Seixas Regina Cele Silveira, Maestrini Heloísa Andrade, Balbino Marcos, Fernandes Thatiana Almeida Pereira, Lima Núbia Vanessa Dos Anjos, Lopes Nara Lídia Vieira, Rodrigues Neto Taurino Dos Santos

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

PURPOSE: This study aimed to compare the safety and effectiveness of intraocular pressure reduction between micropulse transscleral cyclophotocoagulation and "slow cook" transscleral cyclophotocoagulation in patients with refractory primary open-angle glaucoma.

METHODS

We included patients with primary open angle glaucoma with at least 12 months of follow-up. We collected and analyzed data on the preoperative characteristics and postoperative outcomes. The primary outcomes were a reduction of ≥20% of the baseline value (criterion A) and/or intraocular pressure between 6 and 21 mmHg (criterion B).

RESULTS

We included 128 eyes with primary open-angle glaucoma. The preoperative mean intraocular pressure was 25.53 ± 6.40 and 35.02 ± 12.57 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean intraocular pressure was reduced significantly to 14.33 ± 3.40 and 15.37 ± 5.85 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups at the last follow-up, respectively (p=0.110). The mean intraocular pressure reduction at 12 months was 11.20 ± 11.46 and 19.65 ± 13.22 mmHg in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The median preoperative logMAR visual acuity was 0.52 ± 0.69 and 1.75 ± 1.04 in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p<0.001). The mean visual acuity variation was -0.10 ± 0.35 and -0.074 ± 0.16 in the micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p=0.510). Preoperatively, the mean eye drops were 3.44 ± 1.38 and 2.89 ± 0.68 drugs in the micropulse- and "slow cook" transscleral cyclophotocoagulation groups, respectively (p=0.017), but those were 2.06 ± 1.42 and 1.02 ± 1.46 at the end of the study in the "slow cook" and micropulse transscleral cyclophotocoagulation groups, respectively (p<0.001). The success of criterion A was not significant between both groups. Compared with 11 eyes (17.74%) in the "slow cook" transscleral cyclophotocoagulation group, 19 eyes (28.78%) in the micropulse transscleral cyclophotocoagulation group showed complete success (p=0.171). For criterion B, 28 (42.42%) and 2 eyes (3.22%) showed complete success after micropulse- and "slow cook" transscleral cyclophotocoagulation, respectively (p<0.001).

CONCLUSION

Both techniques reduced intraocular pressure effectively.

Для цитирования: Russ Heloisa Helena Abil, Seixas Regina Cele Silveira, Maestrini Heloísa Andrade, Balbino Marcos, Fernandes Thatiana Almeida Pereira, Lima Núbia Vanessa Dos Anjos, Lopes Nara Lídia Vieira, Rodrigues Neto Taurino Dos Santos. Comparison of safety and effectiveness of micropulse transscleral cyclophotocoagulation and "slow cook" diode laser transscleral cyclophotocoagulation in patients with refractory open-angle glaucoma.. Arquivos brasileiros de oftalmologia. 2024. DOI: 10.5935/0004-2749.2023-0103.