MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clon.2026.104190

Медицинская библиотека · Clinical oncology (Royal College of Radiologists (Great Britain)) · 2026

Multicenter Study of Dose Accumulation for Reirradiation: Intercenter Variation in Radiobiological Dose Scaling Introduces Clinically Relevant Differences.

Wahlstedt I, Appelt A, Christiansen R L, Elstrøm U V, Hazell I, Jensen K, Kaplan L P, Knap M M, Kronborg C, Lund M D, Nielsen M, Nielsen M S, Nyeng T B, Nygård L, Ottosson W, Argota Pérez R, Rechner L A, Risumlund S L, Rønde H S, Sand H, Thomsen S N, Tobin R J, Vestergaard S B, Worm E S, Hoffmann L

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

AIMS: We investigated intercenter variation in reirradiation dose accumulation due to (i) varying use of image registration and (ii) varying handling of radiobiological dose scaling in dose accumulation for eight patient cases covering eight different anatomical regions.

MATERIALS AND

METHODS

Eight centers mapped the dose from the previous CT to the reirradiation CT using either rigid or deformable image registration and accumulated doses in (i) physical dose and (ii) equieffective dose in 2 Gy fractions (EQD2) with their institutional α/β values. If used in their clinic, centers could apply dose scaling factors (DSFs) to account for recovery between treatments. We analyzed the accumulated dose to one selected dose-limiting organ at risk (OAR) per patient case.

RESULTS

Intercenter variation in accumulated near-maximum dose (D1%) due to image registration alone (physical dose) ranged from 0.7 Gy for the aorta (lung case) to 9.5 Gy for the mandible (head and neck case). EQD2 scaling increased intercenter variation in accumulated D1% for all OARs, except for the heart (breast case). Application of DSFs changed the D50% intercenter range compared to EQD2-scaled doses from 1.6 Gy to 5.8 Gy for the bladder (anal case), from 0.6 Gy to 1.2 Gy for the chiasm (brain case), and from 7.6 Gy to 10.9 Gy for the bowel bag (rectum case).

CONCLUSION

Lack of consensus in radiobiological-dose scaling considerably increases intercenter variation in reirradiation dose accumulation across a diverse range of tumor sites.

Для цитирования: Wahlstedt I, Appelt A, Christiansen R L, Elstrøm U V, Hazell I, Jensen K, Kaplan L P, Knap M M, Kronborg C, Lund M D, Nielsen M, Nielsen M S, Nyeng T B, Nygård L, Ottosson W, Argota Pérez R, Rechner L A, Risumlund S L, Rønde H S, Sand H, Thomsen S N, Tobin R J, Vestergaard S B, Worm E S, Hoffmann L. Multicenter Study of Dose Accumulation for Reirradiation: Intercenter Variation in Radiobiological Dose Scaling Introduces Clinically Relevant Differences.. Clinical oncology (Royal College of Radiologists (Great Britain)). 2026. DOI: 10.1016/j.clon.2026.104190.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.