MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-015-2242-6

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2015

Open fixation of acute anterior glenoid rim fractures with bioresorbable pins: analysis of clinical and radiological outcome.

Maier Dirk, Izadpanah Kaywan, Ogon Peter, Mützel Maximilian, Bayer Jörg, Südkamp Norbert Paul, Jaeger Martin

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

The purpose of this study was a detailed analysis of clinical and radiological results following open fixation of acute-traumatic, displaced anterior glenoid rim fractures with bioresorbable pins.

MATERIALS AND

METHODS

This retrospective study included 17 patients with glenoid defect sizes ≥20 %, as directly measured in preoperative sagittal en face CT. The mean glenoid defect size was 25.3 % (20-35, SD 4.7). Two or three polylactid pins were used for fixation. Mean age of patients at the time of surgery was 50.1 years (27-71). The mean follow-up period was 6.2 years (2.0-11.1). Follow-up included comprehensive objective and subjective evaluation of shoulder function as well as standard radiographs.

RESULTS

The majority of 15/17 patients obtained good or excellent clinical results according to the absolute and normalized Constant score, the Rowe score, the Oxford shoulder score, the simple shoulder test, the shoulder pain and disability index and the subjective shoulder value. Quality of life (SF-36) showed reference values. Mean or subitem values of all outcome measures did not differ from the contralateral, uninjured side. Radiographically, all fractures healed without secondary dislocation. Radiological signs of glenohumeral arthritis developed in two patients and progressed in two other patients. There were no implant-related complications. No patient experienced glenohumeral instability or had to undergo revision surgery.

CONCLUSIONS

Bioresorbable pin fixation is a feasible and safe method of osteosynthesis for anterior glenoid rim fractures up to a glenoid defect size of about 35 % and enables immediate active range of motion. Good or excellent clinical outcome can be expected and glenohumeral stability is reliably restored. The most common mid- and long-term complication is occurrence or progression of osteoarthritis. The major benefits of bioresorbable pin fixation are redundancy of implant removal, minimal risk of implant-related complications and early functional rehabilitation.

Для цитирования: Maier Dirk, Izadpanah Kaywan, Ogon Peter, Mützel Maximilian, Bayer Jörg, Südkamp Norbert Paul, Jaeger Martin. Open fixation of acute anterior glenoid rim fractures with bioresorbable pins: analysis of clinical and radiological outcome.. Archives of orthopaedic and trauma surgery. 2015. DOI: 10.1007/s00402-015-2242-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.