MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcms.2025.01.003

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2025

Retrospective analyses of additively manufactured subperiosteal jaw implants in the mandible.

Van den Borre Casper, Otero Joel Joshi, Loomans Natalie, Samama Mickaël, Lempert Jakob, Baltensperger Marc, Termont Aurélien, Castro Romain, Mommaerts Maurice Y

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

This multicentre retrospective study evaluates the success rate, adverse events, and patient satisfaction related to additively manufactured subperiosteal jaw implants (AMSJI®) in the mandible. The study analyses data from 40 AMSJI® implants placed between 2017 and beginning of 2024 in 19 patients with severe mandibular atrophy (Cawood-Howell classes IV-VII). The findings reveal a high level of patient satisfaction, and a survival rate of 92.5 % after an average follow-up of 804 days (SD ± 540 days). The most common post-operative adverse events were immediate oedema and temporary infection, which were generally managed with chlorhexidine mouth rinses, antibiotics, and paracetamol. One implant showed increased mobility (movement exceeding 1 mm in any direction) at the time of evaluation. Two other implants were removed due to persistent infection and suppuration, with a third implant scheduled for removal. Patient satisfaction in general was high at the time of the interview, with an average OHIP-14 score of 6.68 (SD ± 7.99) and a NRS score of 51.26 (SD ± 7.63). Mucosal recession (both buccal and lingual) was noted around 13 implants (32.25%); however, patients did not regard this as a functional or aesthetic concern. Within the limitations of a short-term follow-up period, AMSJI in the mandible shows promise as an effective option for rehabilitating patients with severe mandibular atrophy. Despite the positive results, longer-term follow-up is necessary to confirm the implant system's durability and performance over time.

Для цитирования: Van den Borre Casper, Otero Joel Joshi, Loomans Natalie, Samama Mickaël, Lempert Jakob, Baltensperger Marc, Termont Aurélien, Castro Romain, Mommaerts Maurice Y. Retrospective analyses of additively manufactured subperiosteal jaw implants in the mandible.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2025. DOI: 10.1016/j.jcms.2025.01.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.