Short partial doffs of release/relock sockets may effectively stabilize limb fluid volume in prosthesis users with transtibial amputation.

Lanahan Conor R, Coburn Kendrick A, Hafner Brian J, Ballesteros Daniel, Allyn Katheryn J, Friedly Janna L, Ciol Marcia A, Carter Ryan V, Mertens Joseph C, Krout Adam J, Sanders Joan E

СтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

BACKGROUND

A challenge often faced by people with lower extremity amputation is management of prosthetic socket fit due to changes in fluid volume within their residual limb. Prior research suggests that intermittently doffing the prosthetic socket may help stabilize daily residual limb fluid volume.

METHODS

To assess the effects of partial doff duration on residual limb fluid volume retention, participants with transtibial amputation were tested by walking on a treadmill in a controlled, laboratory setting under three conditions. An automated system to release the locking pin and enlarge the socket was used to produce the partial doffing. Percent limb fluid volume changes after partial doffing for 4 min (Short Rest) and for 10 min (Long Rest) were compared with no partial doffing (No Release). Limb fluid volume was monitored using bioimpedance analysis.

FINDINGS: Mean percent fluid volume changes in the posterior region were  -1.2% for No Release, 2.7% for Short Rest, and 1.0% for Long Rest. Short and Long Rests had larger increases than No Release (P = 0.005 and 0.03, respectively); Short and Long Rests were not statistically different (P = 0.10). Eight of the thirteen participants experienced a higher percent fluid volume gain for both release protocols while four experienced a higher percent fluid volume gain for only one release protocol.

INTERPRETATION: A partial doff duration as short as 4 min may be an effective strategy to stabilize limb fluid volume in prosthesis users with transtibial amputation. Trials in at-home settings should be pursued.

Для цитирования: Lanahan Conor R, Coburn Kendrick A, Hafner Brian J, Ballesteros Daniel, Allyn Katheryn J, Friedly Janna L, Ciol Marcia A, Carter Ryan V, Mertens Joseph C, Krout Adam J, Sanders Joan E. Short partial doffs of release/relock sockets may effectively stabilize limb fluid volume in prosthesis users with transtibial amputation.. Clinical biomechanics (Bristol, Avon). 2023. DOI: 10.1016/j.clinbiomech.2023.105986.