Accuracy of flow-void diameters on MR images in diagnosing uterine arteriovenous malformations in patients with pregnancy-related diseases.

Chen Hui-Zhu, Zhao Fu-Min, Liu Ling-Jun, Dai Xiao-Hui, Li Xue-Sheng, Ning Gang, Guo Ying-Kun

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

To evaluate the "flow void" diameter in patients with pregnancy-related diseases with and without uterine AVMs and assess the diagnostic performance of unenhanced MRI for uterine AVMs. From May 2014 to April 2019, 79 patients with pregnancy-related diseases were included, including 36 with and 43 without uterine AVMs confirmed by DSA. On MRI, the diameter of the most prominent "flow void" (hereinafter referred to as fv-D) was measured and compared between patients with and without uterine AVMs. The diagnostic performance of fv-D was estimated with receiver operating characteristic curves. The "flow void" sign was observed in patients with and without uterine AVMs (P > 0.05). The fv-D was significantly larger in patients with uterine AVMs in the myometrium and parametrium than in patients without uterine AVMs (P < 0.0001). The fv-D achieved a reliable diagnostic performance in the myometrium (sensitivity 80.6%, specificity 60.5%, negative predictive value 78.8%, positive predictive value 63%, AUC 0.727, cut-off: > 1.33 mm) and parametrium (sensitivity 97.2%, specificity 67.4%, negative predictive value 96.7%, positive predictive value 71.4%, AUC 0.881, cut-off > 2.6 mm). On MRI, fv-D could diagnose uterine AVMs. The fv-D had a much higher diagnostic efficiency in the parametrium than in the myometrium. The parametrium fv-D greatly improved the diagnostic sensitivity and provides a more accurate, noninvasive method of investigating possible uterine AVMs.

Для цитирования: Chen Hui-Zhu, Zhao Fu-Min, Liu Ling-Jun, Dai Xiao-Hui, Li Xue-Sheng, Ning Gang, Guo Ying-Kun. Accuracy of flow-void diameters on MR images in diagnosing uterine arteriovenous malformations in patients with pregnancy-related diseases.. Scientific reports. 2021. DOI: 10.1038/s41598-021-99209-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.