MRI-guided neurovascular bundle avoidance in high dose rate prostate brachytherapy.

Gerber Drew G, Dresser Sean, Yang Xiaofeng, Qiu Richard L J, Jiang Xiaojun, Desai Sona, Harms Joseph, Patel Sagar A, Hershatter Bruce, Sebastian Nikhil, Dhere Vishal, Liu Tian, Jani Ashesh B, Patel Pretesh R

СтатьяПеревод в очереди

Аннотация

PURPOSE: The neurovascular bundles (NVBs) play a role in erectile function and are not well visualized on ultrasound or computed tomography (CT). In this study we hypothesize that treatment planning MRI will allow avoidance of the NVB during HDR prostate brachytherapy.

MATERIALS AND

METHODS

This was a retrospective review of patients who had HDR prostate brachytherapy as monotherapy (two implants 1-2 weeks apart each delivering 13.5 Gy). All patients underwent TRUS-guided HDR catheter placement followed by CT and MRI simulation. The left and right NVB were contoured on the treatment planning MRI. Standard clinical plans were optimized for prostate coverage and avoidance of organs at risk (OARs). Experimental NVB-sparing plans were generated to add avoidance of the NVBs. Differences between target and OAR doses in the original and NVB-sparing plans were assessed pairwise using a 2-tailed t-test.

RESULTS

34 patients were included and segmentation of the left and right NVB was feasible for all cases. Compared to their paired original plans, NVB-sparing plans reduced left and right NVB D0.01cc (130% vs. 102% and 130% vs. 108%, p < 0.01, respectively). There was no difference in prostate D90 (108% vs 108%, p = 0.19) and V100 (96.1 vs 95.9%, p = 0.17) between plans; prostate V150% (35.8% vs. 34.7%, p < 0.01) and V200% (14.0% vs 13.4%, p < 0.01) slightly decreased in the NVB-sparing plans. Mean bladder V75 (0.3 cc), rectum V75 (0.2 cc), and urethra V125 (0.03 cc) were similar between plans.

CONCLUSIONS

Using MRI-based treatment planning, NVB-sparing prostate HDR brachytherapy is feasible and merits further study.

Для цитирования: Gerber Drew G, Dresser Sean, Yang Xiaofeng, Qiu Richard L J, Jiang Xiaojun, Desai Sona, Harms Joseph, Patel Sagar A, Hershatter Bruce, Sebastian Nikhil, Dhere Vishal, Liu Tian, Jani Ashesh B, Patel Pretesh R. MRI-guided neurovascular bundle avoidance in high dose rate prostate brachytherapy.. Brachytherapy. 2025. DOI: 10.1016/j.brachy.2025.08.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.