ACS sensors · 2026
Deep-Eutectic-Solvent-Enabled Polyampholyte/MXene Eutectogels for Environmentally Tolerant Wearable Respiratory Monitoring.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Liu Jiahao, Tang Xueming, Zhang Lei, Tian Ruobing, Wang Xinli, Miao Bin, Sun Yuanna, Wang Junbo, Yang Hao, Zheng Wanxiang
Аннотация
Conductive hydrogels are promising for wearable electronics; however, freezing and dehydration of their water-rich networks often compromise mechanical compliance, electrical conductivity, and sensing reliability. Here, we report a deep-eutectic-solvent-enabled polyampholyte/MXene eutectogel constructed from a betaine/ethylene glycol deep eutectic solvent (DES), a dynamically crosslinked polyampholyte network formed from sodium p-styrenesulfonate (NaSS) and quaternized dimethylaminoethyl acrylate (DMAEA-Q), and MXene nanosheets. MXene establishes the principal conductive pathways, while DES-mediated molecular interactions alter the local electronic structure of representative polyampholyte-associated complexes. Density functional theory calculations show that replacing water with DES redistributes the frontier molecular orbitals and decreases the calculated HOMO-LUMO energy difference of the NaSS-DMAEA-Q complex from 4.60 to 4.34 eV, consistent with a more favorable local charge-transfer environment. Correspondingly, at the same MXene loading, the DES-based eutectogel reaches a conductivity of 1.51 S/m, more than twice that of the water-based hydrogel (0.71 S/m). The DES hydrogen-bonding network also suppresses crystallization and solvent evaporation, while reversible ionic-pair interactions provide high deformability and adhesion. This formulation exhibits a fracture strain of approximately 630%, an adhesion strength of 47.9 kPa, a crystallization peak at -74.3 °C, and 94% mass retention after 30 days. The resulting sensor enables strain, pressure, temperature, and respiratory monitoring. Furthermore, integration with an STM32-based signal-acquisition system and a deep neural network enables four-class recognition of respiratory signals collected from the mouth, nose, abdomen, and chest, achieving an internal validation accuracy of 95.06%, while a threshold-based warning module provides real-time identification of apnea-like respiratory interruptions.