INTRODUCTION

Virtual surgical planning (VSP) and patient-specific implants (PSI) have become standard in orthognathic surgery, demonstrating accuracy and stability comparable with miniplates.

AIMS: To compare postoperative skeletal stability of Le Fort I osteotomy using VSP with PSIs versus conventional cast model surgery with miniplate fixation in patients with clefts.

METHODS

Retrospective analysis of lateral cephalograms and medical records of patients who underwent Le Fort I osteotomy between 2017 and 2023 at the Cleft Palate and Craniofacial Center, Helsinki University Hospital. Horizontal and vertical surgical advancement and relapse were assessed by superimposing preoperative, immediate, and one-year postoperative cephalometric tracings. Statistical analyses included independent samples t-, Mann-Whitney U-, Chi-squared and Fischer's exact test.

RESULTS

Fifty-nine non-growing patients with cleft lip and/or palate (29 males; median age 18.9 years) were categorized into two groups based on the fixation method (19 PSI, 40 miniplate). Mean maxillary advancement was greater with PSIs than miniplates (7.1 mm vs. 4.3 mm; p < 0.001). Mean vertical movement was -0.8 mm with PSIs vs. -3.8 mm with miniplates (p < 0.001), reflecting more impactions in the PSI group. Horizontal and vertical relapses were significantly smaller in the PSI group (horizontal: 0.28 mm vs. 0.9 mm, 4% vs. 21% of advancement; p < 0.001; vertical: 0.81 mm vs. 1.6 mm, 30% vs. 41% of movement; p = 0.004). Horizontal advancement correlated with relapse only with miniplates (r = 0.329, p = 0.038).

CONCLUSIONS

PSI fixation in cleft Le Fort I osteotomy seems to provide greater horizontal and vertical stability than miniplates.

Для цитирования: Rouhiainen Vilma, Heliövaara Arja, Leikola Junnu, Suojanen Juho, Juuri Emma. Patient-specific implants are more stable than conventional miniplates in Le Fort I osteotomy in patients with clefts.. JPRAS open. 2026. DOI: 10.1016/j.jpra.2026.07.010.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.