MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jcla.70174

Медицинская библиотека · Journal of clinical laboratory analysis · 2026

Diagnostic Concordance of Two- and Three-Gene SARS-CoV-2 Molecular Assays in Cameroon: Implications for Efficient Pandemic Response in Low- and Middle-Income Countries.

Ngueko Aurelie Minelle Kengni, Ndjeyep Sandrine Claire Djupsa, Semengue Ezechiel Ngoufack Jagni, Nka Alex Durand, Chenwi Collins Ambe, Ka'e Aude Christelle, Bouba Yagai, Gabisa Jeremiah Efakika, Molimbou Evariste, Etame Naomi-Karell, Tekoh Tatiana Anim-Keng, Mundo Rachel Audrey Nayang, Tueguem Pamela Patricia, Mekel Vincent Kamael, Mba Hugues, Takou Désiré, Beloumou Grace Angong, Tchouaket Michel Carlos Tommo, Fotso Larissa Gaelle Moko, Ayuk Derrick Tambe, Ouankou Christian Ngongang, Alteri Claudia, Colagrossi Luna, Boum Yap, Ekane Halle Gregory Eddy, Ceccherini-Silberstein Francesca, Colizzi Vittorio, Ndembi Nicaise, Njamnshi Alfred K, Ndjolo Alexis, Perno Carlo-Federico, Santoro Maria-Mercedes, Fokam Joseph

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The scale-up of molecular assays for diagnosing emerging pathogens has increased in low-and-middle-income countries (LMICs) since the advent of COVID-19. We herein evaluated the diagnostic concordance of three different assays for SARS-CoV-2 in Cameroon.

METHODS

A laboratory-based comparative study was performed on nasopharyngeal samples collected between March-2020 to March-2023 from the biobank of Chantal Biya International Reference Centre (CIRCB), Yaoundé-Cameroon. Samples were analyzed using DaAn Gene (N/ORF1ab-genes), ThermoFisher (N/ORF1ab/S-genes), and GeneXpert (N2/E-genes). Validated cycle thresholds (CT) for positivity were CT < 37 for DaAn Gene/ThermoFisher and CT < 40 for GeneXpert. Cohen's Kappa coefficient evaluated diagnostic concordance with DaAn Gene as reference.

RESULTS

We analysed 249 samples (55.8% males, median-age [IQR], 36 [27-50] years including 21.3% symptomatic participants). Overall positivity rates (median [IQR]) were 55.0% (CT: 30.6 [23.1-35.5]); 53.4% (CT: 26.6 [21.2-30.9]); 22.1% (CT: 32.7 [26.9-36.1]) for GeneXpert, DaAn Gene and ThermoFisher respectively. GeneXpert showed stronger concordance with DaAn Gene (83.1%; k = 0.66, 95% CI: 0.57-0.75) than ThermoFisher (67.9%; k = 0.38, 95% CI: 0.29-0.47). At validated thresholds, GeneXpert showed higher positive agreement with DaAn Gene (85.0%, 113/133) as compared to ThermoFisher (41.3%, 55/133), while maintaining comparable negative agreement (81.0% [GeneXpert] and 98.3% [ThermoFisher]). At low CTs (< 20) however, positive agreement with DaAn Gene was high for GeneXpert (100%, 15/15) and ThermoFisher (93.3%, 14/15).

CONCLUSION

GeneXpert exhibits superiority over ThermoFisher in detecting cases of COVID-19. As expected, agreement between two- and three-genes assays at CT < 20 was excellent, suggesting interoperability of these platforms during outbreaks for high viral loads cases. However, two-genes assays may be decisive to guide decision-making for effective public health response while facing intermediate to low-level viral loads in LMICs.

Для цитирования: Ngueko Aurelie Minelle Kengni, Ndjeyep Sandrine Claire Djupsa, Semengue Ezechiel Ngoufack Jagni, Nka Alex Durand, Chenwi Collins Ambe, Ka'e Aude Christelle, Bouba Yagai, Gabisa Jeremiah Efakika, Molimbou Evariste, Etame Naomi-Karell, Tekoh Tatiana Anim-Keng, Mundo Rachel Audrey Nayang, Tueguem Pamela Patricia, Mekel Vincent Kamael, Mba Hugues, Takou Désiré, Beloumou Grace Angong, Tchouaket Michel Carlos Tommo, Fotso Larissa Gaelle Moko, Ayuk Derrick Tambe, Ouankou Christian Ngongang, Alteri Claudia, Colagrossi Luna, Boum Yap, Ekane Halle Gregory Eddy, Ceccherini-Silberstein Francesca, Colizzi Vittorio, Ndembi Nicaise, Njamnshi Alfred K, Ndjolo Alexis, Perno Carlo-Federico, Santoro Maria-Mercedes, Fokam Joseph. Diagnostic Concordance of Two- and Three-Gene SARS-CoV-2 Molecular Assays in Cameroon: Implications for Efficient Pandemic Response in Low- and Middle-Income Countries.. Journal of clinical laboratory analysis. 2026. DOI: 10.1002/jcla.70174.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.