MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.euf.2025.04.026

Медицинская библиотека · European urology focus · 2025

Ultrasound for the Diagnosis of Testicular Torsion: A Systematic Review and Meta-analysis of Diagnostic Accuracy.

Alexander Cameron E, Warren Hannah, Light Alexander, Agarwal Ridhi, Asif Aqua, Chow Bing Jie, Clement Keiran, Chan Vinson, Zimmermann Eleanor, Khadhouri Sinan, Eyskens Pieter Jan, Shah Taimur T, Nathan Arjun, Byrnes Kevin, Bhatt Nikita, Mani Nick, Yuhong Yuan Cathy, Sidhu Paul S, Takwoingi Yemisi, Kasivisvanathan Veeru

СтатьяСистематический обзорМетаанализПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

Uncertainty regarding the diagnostic accuracy of ultrasound for testicular torsion (TT) and a lack of high-level evidence to inform international guidelines have led to significant global variation in its use. The objective of this study was to assess the diagnostic accuracy of ultrasound for TT.

METHODS

This systematic review was undertaken in accordance with the Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. A comprehensive electronic search strategy was applied up to January 4, 2024. Colour Doppler sonography (CDS) was the primary index test, with surgical scrotal exploration or clinical follow-up as the reference standard. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to assess the risk of bias and applicability. Meta-analyses were performed using bivariate models.

KEY FINDINGS AND LIMITATIONS: Sixty-three studies met the inclusion criteria; 54 (85.7%) assessed CDS, and the others assessed spectral doppler sonography (n = 6), contrast enhanced ultrasound (n = 1), or an alternative combination of ultrasound technologies (n = 2). The summary sensitivity (95% confidence interval [CI]) and specificity (95% CI) of CDS for the diagnosis of TT were 95.3% (91.4-97.5) and 98.3% (96.2-99.3), respectively (42 studies, 4422 participants). Patient selection (related to the risk of bias and applicability concern) was identified as the domain of the greatest methodological concern on QUADAS-2 assessment.

CONCLUSIONS AND CLINICAL IMPLICATIONS: CDS has high diagnostic accuracy for TT. The ideal patient pathway for suspected TT should integrate timely access to ultrasound alongside clinical assessment, with careful patient counselling.

Для цитирования: Alexander Cameron E, Warren Hannah, Light Alexander, Agarwal Ridhi, Asif Aqua, Chow Bing Jie, Clement Keiran, Chan Vinson, Zimmermann Eleanor, Khadhouri Sinan, Eyskens Pieter Jan, Shah Taimur T, Nathan Arjun, Byrnes Kevin, Bhatt Nikita, Mani Nick, Yuhong Yuan Cathy, Sidhu Paul S, Takwoingi Yemisi, Kasivisvanathan Veeru. Ultrasound for the Diagnosis of Testicular Torsion: A Systematic Review and Meta-analysis of Diagnostic Accuracy.. European urology focus. 2025. DOI: 10.1016/j.euf.2025.04.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.