MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/aog.0b013e31825b9086

Медицинская библиотека · Obstetrics and gynecology · 2012

Using a 16-French resectoscope as an alternative device in the treatment of uterine lesions: a randomized controlled trial.

Ricciardi Raffaele, Lanzone Antonio, Tagliaferri Valeria, Di Florio Christian, Ricciardi Luigi, Selvaggi Luigi, Guido Maurizio

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To compare a 16-French resectoscope with a 22-French resectoscope and a 15-French hysteroscope for the treatment of uterine cavity lesions.

METHODS

This was a prospective, randomized study of women with endometrial polyps or submucous myomas treated with a 16-French resectoscope, a traditional 22-French resectoscope, or a 15-French hysteroscope. The operating time, volume of distension medium delivered, discharge time, and patient discomfort by visual analog scale were recorded. Data were compared by one-way and two-way analysis of variance as appropriate.

RESULTS

Four hundred one women were included in the analysis. All four parameters showed lower values in the 16-French resectoscope group (142 women) compared with the 15-French hysteroscope group (132 women; P<.01). The mean operating time was 10.87±2.87 minutes in the 22-French group (127 women), 8.33±2.94 minutes in the 16-French group, and 17.11±6.86 minutes in the 15-French group. The mean volume of distension medium delivered was 1,043±230 mL in the 22-French group, 991±442 mL in the 16-French group, and 1,489±566 mL in the 15-French group. The mean discharge time was 1.99±0.72 hours in the 22-French group, 1.08±0.18 hours in the 16-French group, and 1.89±0.68 hours in the 15-French group. Finally, the mean visual analog scale scores were 2.10±0.97 in the 22-French group, 1.93±1.03 in the 16-French group, and 4.00±1.61 in the 15-French group. An analysis of patients subdivided according to the lesion size (less than 1.5 cm and more than 1.5 cm in diameter) showed similar results.

CONCLUSION

The new 16-French resectoscope is effective for the "see and treat" approach for both small (less than 1.5 cm diameter) and large (more than 1.5 cm diameter) uterine lesions.

Для цитирования: Ricciardi Raffaele, Lanzone Antonio, Tagliaferri Valeria, Di Florio Christian, Ricciardi Luigi, Selvaggi Luigi, Guido Maurizio. Using a 16-French resectoscope as an alternative device in the treatment of uterine lesions: a randomized controlled trial.. Obstetrics and gynecology. 2012. DOI: 10.1097/aog.0b013e31825b9086.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.