MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2003.11.010

Медицинская библиотека · Ultrasound in medicine & biology · 2004

Wavelet denoising of displacement estimates in elastography.

Techavipoo Udomchai, Varghese Tomy

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Wavelet shrinkage denoising of the displacement estimates to reduce noise artefacts, especially at high overlaps in elastography, is presented in this paper. Correlated errors in the displacement estimates increase dramatically with an increase in the overlap between the data segments. These increased correlated errors (due to the increased correlation or similarity between consecutive displacement estimates) generate the so-called "worm" artefact in elastography. However, increases in overlap on the order of 90% or higher are essential to improve axial resolution in elastography. The use of wavelet denoising significantly reduces errors in the displacement estimates, thereby reducing the worm artefacts, without compromising on edge (high-frequency or detail) information in the elastogram. Wavelet denoising is a term used to characterize noise rejection by thresholding the wavelet coefficients. Worm artefacts can also be reduced using a low-pass filter; however, low-pass filtering of the displacement estimates does not preserve local information such as abrupt change in slopes, causing the smoothing of edges in the elastograms. Simulation results using the analytic 2-D model of a single inclusion phantom illustrate that wavelet denoising produces elastograms with the closest correspondence to the ideal mechanical strain image. Wavelet denoising applied to experimental data obtained from an in vitro thermal lesion phantom generated using radiofrequency (RF) ablation also illustrates the improvement in the elastogram noise characteristics.

Для цитирования: Techavipoo Udomchai, Varghese Tomy. Wavelet denoising of displacement estimates in elastography.. Ultrasound in medicine & biology. 2004. DOI: 10.1016/j.ultrasmedbio.2003.11.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.