PURPOSE: The objective of this study was to evaluate variations in entrance skin dose across different anatomical regions of a head phantom and to present entrance skin dose results obtained from a limited number of measurement points. By identifying key anatomical landmarks, the study aims to rationalize the number of entrance skin dose measurement points using thermoluminescence dosimeters (TLDs).

MATERIALS AND

METHODS

A tissue-equivalent head and neck phantom was examined with a 1-shot cephalometric X-ray machine under standardized settings. A detailed measurement protocol (140 TLDs for protocol 1) was compared to 3 alternative protocols using fewer measurement points (40 TLDs for protocol 2, 30 TLDs for protocol 3, and 6 TLDs for protocol 4).

RESULTS

Protocol 1 yielded an average entrance skin dose of 1.042 mSv, with higher doses at the parotid gland and above the left eye corner. Protocols 2 and 3 produced similar mean doses (1.003 mSv and 1.04 mSv, respectively), demonstrating that fewer dosimeters can still generate reliable results. Protocol 4, which targeted radiosensitive sites such as the thyroid and parotid glands, provided a comparable mean entrance skin dose for the beam-facing side (1.76 mSv) relative to the other protocols.

CONCLUSION

These findings suggest that the selected dosimetry approach is effective in assessing exposure to key tissues such as the skin. The results provide a foundation for a more representative, reproducible, and cost-effective dosimetric method in cephalometric radiography.

Для цитирования: Ilhan Muhammed, Menz Roman, Verna Carlalberta, Bornstein Michael M, Dagassan-Berndt Dorothea C. Identification of key measurement points for accurate surface radiation dose assessment in cephalometric radiography.. Imaging science in dentistry. 2025. DOI: 10.5624/isd.20250143.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.