Use of suture-mediated closure device system after inadvertent medport placement in the subclavian artery leading to multi-focal ischaemic infarct: a case report.

Rodríguez-Santiago María A, Rodríguez-Cruz Edwin, Mesa-Pabon Marcel A

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Totally implantable venous access devices or chemoports are progressively being used in oncologic patients for long-term chemotherapy administration. We present the case of an iatrogenic arterial catheter placement in the aortic arch complicated with multi-focal ischaemic stroke.

CASE SUMMARY: A case of a 73-year-old woman with a history of hypertension, diabetes mellitus, pineal gland tumour status post ventriculoperitoneal shunt, and breast and bladder cancer presented with a 2-week history of impaired balance, dysarthria, and right-sided facial drop. The chemoport was placed less than a month prior to the onset of symptoms at another institution. A brain magnetic resonance imaging revealed a left hemispheric supra- and infra-tentorial subacute ischaemic infarcts. The head and neck computed tomography angiography notably showed a misplaced venous port at the left subclavian artery with a distal tip projecting towards the ascending aortic arch, revealing the most likely aetiology of multi-focal ischaemic stroke. The patient underwent successful subclavian artery catheter extraction and endovascular repair with a suture-mediated closure device system without complications.

DISCUSSION: Subclavian artery iatrogenic cannulation may lead to catastrophic outcomes, including stroke. A high level of suspicion for venous port misplacement must be entertained when ipsilateral multi-focal ischaemic infarct occurs in time relation to catheter placement. Conducting an endovascular catheter retrieval and using a suture-mediated closure device is an alternative approach to manual compression in locations where achieving an haemostasis is challenging. A suture-mediated closure device system might be useful for anatomy not amenable to manual compression, such as the subclavian artery.

Для цитирования: Rodríguez-Santiago María A, Rodríguez-Cruz Edwin, Mesa-Pabon Marcel A. Use of suture-mediated closure device system after inadvertent medport placement in the subclavian artery leading to multi-focal ischaemic infarct: a case report.. European heart journal. Case reports. 2024. DOI: 10.1093/ehjcr/ytae565.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.