Effect of anterior segment structure on vault and position after implantable collamer lens implantation.

Wang Qin, Chen Xiao, Li Li, Zhou Lin, Gao Yang, Shen Li, Peng Shaomin, Zhou Qizhi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the effect of anterior-segment structure on vault and position after implantable collamer lens (ICL) implantation using ultrasound biomicroscopy.

METHODS

The retrospective case-control study included insufficient vault eyes (<250 µm), ideal vault eyes (250-750 µm), and excessive vault eyes (>750 µm). The preoperative biometric parameters of the anterior-segment structure and basic data between the three groups were analyzed using one-way analysis of variance.

RESULTS

There were significant differences ( P < 0.05) between the three groups in maximum ciliary body thickness (CBT max ), iris-zonule distance (IZD), and trabecular-ciliary angle (TCA). The vault gradually decreased as CBT max decreased and TCA increased. In the pairwise comparison, the CBT max comparison between the insufficient vault (<250 µm) group and the excessive vault (>750 µm) group was statistically significant ( P = 0.024, 95% CI: -0.17-0.017 µm); the TCA comparison between the insufficient vault (<250 µm) group and the excessive vault (>750 µm) group was statistically significant ( P = 0.005, 95% CI: 1.78°-12.15°); The IZD comparison between the insufficient vault (<250 µm) group and the excessive vault (>750 µm) group was statistically significant ( P = 0.037, 95% CI: 0.0027-0.1119 µm). The analysis of 284 ICL haptics locations showed that there were 16.67%, 32.69%, and 70.83% haptics located in the ciliary sulcus in three groups, respectively.

CONCLUSION

The vault and ICL haptics position are related to anterior-segment structure. A thinner and posteriorly positioned ciliary body would increase the risk of low vault and fewer ICL haptics located in the ciliary sulcus after ICL implantation. This provides guidance for the selection of the ICL size and placement position before surgery.

Для цитирования: Wang Qin, Chen Xiao, Li Li, Zhou Lin, Gao Yang, Shen Li, Peng Shaomin, Zhou Qizhi. Effect of anterior segment structure on vault and position after implantable collamer lens implantation.. Indian journal of ophthalmology. 2024. DOI: 10.4103/ijo.ijo_2663_23.