MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41433-026-04876-5

Медицинская библиотека · Eye (London, England) · 2026

Endophthalmitis following glaucoma drainage device surgery.

Elhusseiny Abdelrahman M, Alzein Ahmad F, Dihan Qais A, Serhan Hashem Abu, Sebhat Aron M, ElSheikh Reem H, Muayad Jawad, Yannuzzi Nicolas A, Bitrian Elena, Chang Ta C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To evaluate the risk of endophthalmitis in glaucoma patients undergoing glaucoma drainage device (GDD) surgery.

METHODS

This retrospective cohort study identified glaucoma patients utilising TriNetX's database who underwent GDD between 2004 and 2024 without a prior history of glaucoma surgery. Kaplan-Meier survival analysis estimated the cumulative incidence of endophthalmitis and a Cox proportional hazards model, adjusted for demographic and clinical covariates, was used to calculate adjusted hazard ratios (aHRs) and confidence intervals (CIs) comparing outcomes between patients who underwent tube shunt surgery versus trabeculectomy. A scleral buckle (SB) cohort was added as a second comparator to GDD to contextualise infection risk related to hardware without bleb formation.

RESULTS

The GDD cohort included 12,849 patients (mean age 62.7 ± 19 years), compared with 9,006 trabeculectomy patients (67.9 ± 14.1) and 3,097 SB patients (45.1 ± 18.7). After GDD surgery, the cumulative incidence of endophthalmitis was 0.82% at 1, 1.57% at 3 and 1.87% at 5 years, compared with 0.47%, 0.78% and 0.96% following trabeculectomy and 0.19%, 0.23% and 0.39% following SB. In Cox models, there was no significant difference in hazard between GDD and trabeculectomy at any timepoint. However, GDD was associated with higher risk than SB at 30 days (aHR 5.43, CI: 1.28-23.08, 1 year (aHR 3.36, 95% CI 1.88-5.99) and 5 years (aHR 3.71, 95% CI 2.40-5.73).

CONCLUSION

Endophthalmitis is an uncommon but persistent risk after GDD surgery. Although long-term risk was comparable between GDD and trabeculectomy, GDD implantation carried a higher risk than SB.

Для цитирования: Elhusseiny Abdelrahman M, Alzein Ahmad F, Dihan Qais A, Serhan Hashem Abu, Sebhat Aron M, ElSheikh Reem H, Muayad Jawad, Yannuzzi Nicolas A, Bitrian Elena, Chang Ta C. Endophthalmitis following glaucoma drainage device surgery.. Eye (London, England). 2026. DOI: 10.1038/s41433-026-04876-5.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.