MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/1541-4337.13358

Медицинская библиотека · Comprehensive reviews in food science and food safety · 2024

Recent advances and trends in innovative biosensor-based devices for heavy metal ion detection in food.

Aihaiti Aihemaitijiang, Wang Jingkang, Zhang Wenrui, Shen Mingping, Meng Fanxing, Li Zongda, Zhang Yukun, Ren Mengyao, Zhang Minwei

СтатьяОбзорПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Low-cost, reliable, and efficient biosensors are crucial in detecting residual heavy metal ions (HMIs) in food products. At present, based on distance-induced localized surface plasmon resonance of noble metal nanoparticles, enzyme-mimetic reaction of nanozymes, and chelation reaction of metal chelators, the constructed optical sensors have attracted wide attention in HMIs detection. Besides, based on the enrichment and signal amplification strategy of nanomaterials on HMIs and the construction of electrochemical aptamer sensing platforms, the developed electrochemical biosensors have overcome the plague of low sensitivity, poor selectivity, and the inability of multiplexed detection in the optical strategy. Moreover, along with an in-depth discussion of these different types of biosensors, a detailed overview of the design and application of innovative devices based on these sensing principles was provided, including microfluidic systems, hydrogel-based platforms, and test strip technologies. Finally, the challenges that hinder commercial application have also been mentioned. Overall, this review aims to establish a theoretical foundation for developing accurate and reliable sensing technologies and devices for HMIs, thereby promoting the widespread application of biosensors in the detection of HMIs in food.

Для цитирования: Aihaiti Aihemaitijiang, Wang Jingkang, Zhang Wenrui, Shen Mingping, Meng Fanxing, Li Zongda, Zhang Yukun, Ren Mengyao, Zhang Minwei. Recent advances and trends in innovative biosensor-based devices for heavy metal ion detection in food.. Comprehensive reviews in food science and food safety. 2024. DOI: 10.1111/1541-4337.13358.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.