MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0244963

Медицинская библиотека · PloS one · 2020

Emergency ventilator for COVID-19.

King William P, Amos Jennifer, Azer Magdi, Baker Daniel, Bashir Rashid, Best Catherine, Bethke Eliot, Boppart Stephen A, Bralts Elisabeth, Corey Ryan M, Dietkus Rachael, Durack Gary, Elbel Stefan, Elliott Greg, Fava Jake, Goldenfeld Nigel, Goldstein Molly H, Hayes Courtney, Herndon Nicole, Jamison Shandra, Johnson Blake, Johnson Harley, Johnson Mark, Kolaczynski John, Lee Tonghun, Maslov Sergei, McGregor Davis J, Milner Derek, Moller Ralf, Mosley Jonathan, Musser Andy, Newberger Max, Null David, O'Bryan Lucas, Oelze Michael, O'Leary Jerry, Pagano Alex, Philpott Michael, Pianfetti Brian, Pille Alex, Pizzuto Luca, Ricconi Brian, Rubessa Marcello, Rylowicz Sam, Shipley Clifford, Singer Andrew C, Stewart Brian, Switzky Rachel, Tawfick Sameh, Wheeler Matthew, White Karen, Widloski Evan M, Wood Eric, Wood Charles, Wooldridge Abigail R

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The COVID-19 pandemic disrupted the world in 2020 by spreading at unprecedented rates and causing tens of thousands of fatalities within a few months. The number of deaths dramatically increased in regions where the number of patients in need of hospital care exceeded the availability of care. Many COVID-19 patients experience Acute Respiratory Distress Syndrome (ARDS), a condition that can be treated with mechanical ventilation. In response to the need for mechanical ventilators, designed and tested an emergency ventilator (EV) that can control a patient's peak inspiratory pressure (PIP) and breathing rate, while keeping a positive end expiratory pressure (PEEP). This article describes the rapid design, prototyping, and testing of the EV. The development process was enabled by rapid design iterations using additive manufacturing (AM). In the initial design phase, iterations between design, AM, and testing enabled a working prototype within one week. The designs of the 16 different components of the ventilator were locked by additively manufacturing and testing a total of 283 parts having parametrically varied dimensions. In the second stage, AM was used to produce 75 functional prototypes to support engineering evaluation and animal testing. The devices were tested over more than two million cycles. We also developed an electronic monitoring system and with automatic alarm to provide for safe operation, along with training materials and user guides. The final designs are available online under a free license. The designs have been transferred to more than 70 organizations in 15 countries. This project demonstrates the potential for ultra-fast product design, engineering, and testing of medical devices needed for COVID-19 emergency response.

Для цитирования: King William P, Amos Jennifer, Azer Magdi, Baker Daniel, Bashir Rashid, Best Catherine, Bethke Eliot, Boppart Stephen A, Bralts Elisabeth, Corey Ryan M, Dietkus Rachael, Durack Gary, Elbel Stefan, Elliott Greg, Fava Jake, Goldenfeld Nigel, Goldstein Molly H, Hayes Courtney, Herndon Nicole, Jamison Shandra, Johnson Blake, Johnson Harley, Johnson Mark, Kolaczynski John, Lee Tonghun, Maslov Sergei, McGregor Davis J, Milner Derek, Moller Ralf, Mosley Jonathan, Musser Andy, Newberger Max, Null David, O'Bryan Lucas, Oelze Michael, O'Leary Jerry, Pagano Alex, Philpott Michael, Pianfetti Brian, Pille Alex, Pizzuto Luca, Ricconi Brian, Rubessa Marcello, Rylowicz Sam, Shipley Clifford, Singer Andrew C, Stewart Brian, Switzky Rachel, Tawfick Sameh, Wheeler Matthew, White Karen, Widloski Evan M, Wood Eric, Wood Charles, Wooldridge Abigail R. Emergency ventilator for COVID-19.. PloS one. 2020. DOI: 10.1371/journal.pone.0244963.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.