Case report: Introduction of an Ahmed valve implant tube into the ciliary sulcus using a guide-wire.

Leite João, Figueiredo Ana, Reis Rita, Sampaio Isabel, Menéres Maria João

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Glaucoma is a progressive optic neuropathy and it is the main cause of irreversible blindness worldwide. Intraocular pressure (IOP) is the only modifiable one and trabeculectomy is commonly considered the surgical "gold standard" to decrease IOP. In particular cases, other kind of surgeries, as the Ahmed Glaucoma Valve (AGV) implant, are a reliable alternative. Usually, the silicone tube of AGV surgery is inserted into the anterior chamber. Sometimes it is necessary to place the AGV silicone tube in the ciliary sulcus, especially in cases of endothelial decompensation. This surgical procedure is not always easy to perform.

CASE PRESENTATION: This article describes and presents a technique for inserting the AGV tube into the posterior chamber using a guide-wire, in a total of 12 cases are reported. This procedure has been mostly applied in a group of pseudophakic patients who need AGV placement to control elevated IOP. In exceptional situations, this procedure was applied in pseudophakic patients previously with AGV tube implanted in the anterior chamber and with loss of endothelial cells or in phakic patients with previously implanted AGV anterior chamber tube, simultaneously to cataract surgery.

CONCLUSION

The purpose of these cases presentations attended at our service is to demonstrate the passage of the AGV silicone tube was performed with the aid of a guide wire.

Для цитирования: Leite João, Figueiredo Ana, Reis Rita, Sampaio Isabel, Menéres Maria João. Case report: Introduction of an Ahmed valve implant tube into the ciliary sulcus using a guide-wire.. European journal of ophthalmology. 2024. DOI: 10.1177/11206721241247584.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.