MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/11206721241235430

Медицинская библиотека · European journal of ophthalmology · 2024

Ultrasound cyclo plasty in advanced glaucoma: Intermediate-term success, predictors for failure and complications.

Almobarak Faisal A, Alrubean Ahmed, Alsarhani Waleed K, Aljenaidel Abdullah

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report the intermediate-term success rate of ultrasound cyclo plasty (UCP), predictors for failure and complications in advanced glaucoma.

METHODS

This study included patients with advanced glaucoma who underwent UCP. The main outcome measures were intraocular pressure (IOP), the number of antiglaucoma medications, and the presence of complications. Success was defined as an IOP reduction ≥30% and IOP between 6 mmHg and 18 mmHg with no vision-threatening complications. Cox proportional hazard regression analysis was performed to identify possible predictors for failure.

RESULTS

We included 65 eyes of 58 patients in the study. The mean IOP and number of antiglaucoma medications decreased significantly from 27.60 ± 5.5 mmHg and 3.40 ± 0.9 at baseline to 17.80 ± 8.0 mmHg (35.51% reduction) and 2.43 ± 1.3 at 12 months and 17.10 ± 8.2 mmHg (38.04% reduction) and 2.41 ± 1.5 at 24 months, respectively (p < 0.01 for both). The success rates were 66.2% (43/65) and 72.4% (21/29), while the failure rates were 33.8% (22/65) and 27.6% (8/29) at 12 and 24 months postoperatively, respectively. The cumulative probabilities of overall success were 67.7 ± 5.8% and 33.8 ± 5.9% at 12 and 24 months, respectively. High baseline IOP and history of old glaucoma surgery were associated with a higher risk for failure (Hazard ratio = 1.10 and 5.82, p = 0.03 and p < 0.01, respectively). The most common complications were anterior chamber reaction (18.5%) and cataract development/progression (15.4%). Two eyes (3.1%) developed phthisis bulbi.

CONCLUSIONS

Although UCP is effective in lowering IOP in eyes with advanced glaucoma, the intermediate-term success rates were moderate.

Для цитирования: Almobarak Faisal A, Alrubean Ahmed, Alsarhani Waleed K, Aljenaidel Abdullah. Ultrasound cyclo plasty in advanced glaucoma: Intermediate-term success, predictors for failure and complications.. European journal of ophthalmology. 2024. DOI: 10.1177/11206721241235430.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.