DOI 10.1016/j.apradiso.2026.112824

Медицинская библиотека · Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2026

Influence of precursor purity on the low-dose TL and OSL response of flux-grown pure α-Al2O3.

Rodrigues C M C, Saraiva J G, Alves L C, Rodrigues A L, Gonçalves A P, Peralta L

СтатьяПеревод в очереди

Аннотация

Luminescence dosimetry continues to advance through efforts to improve detector sensitivity, stability, and cost-effectiveness. Within this scope, Al2O3 crystals were produced by the flux-growth method, a low-cost crystal growth technique, using MoO3 precursors with purities from 99.0% to 99.95%, and Al2O3 of 99.99% and 99.999% purity. Elemental characterization was pursued using μ-PIXE and PIGE. The thermoluminescence (TL) and optically stimulated luminescence (OSL) characteristic response to 90Sr/90Y β-radiation over the dose range of 30 mGy to 15 Gy was investigated, with emphasis on the role of precursor purity, using the Risø-DA20 reader. Variations in MoO3 purity resulted in differences in trap distribution, reflected in both TL and OSL behavior. All samples showed supralinear TL and OSL dose-response without saturation within the studied range and demonstrated high signal reproducibility (< 5%). Increasing MoO3 and Al2O3 precursor purity led to substantial improvements to TL and OSL intensity by up to 67× and 14×, respectively, and significantly improved low-dose sensitivity. The results confirm that precursor purity is a critical parameter controlling luminescence efficiency in flux-grown sapphire. Overall, the flux-growth method emerges as a promising and economically attractive route for producing Al2O3 dosimetric materials, including for low-dose applications, using the appropriate starting materials. Further optimization of growth conditions or targeted doping strategies may enable additional improvements in detector sensitivity and performance.

Для цитирования: Rodrigues C M C, Saraiva J G, Alves L C, Rodrigues A L, Gonçalves A P, Peralta L. Influence of precursor purity on the low-dose TL and OSL response of flux-grown pure α-Al2O3.. Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine. 2026. DOI: 10.1016/j.apradiso.2026.112824.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.