MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0273395

Медицинская библиотека · PloS one · 2022

Variation in clinical target volume delineation in postoperative radiotherapy for biliary tract cancer.

Koo Taeryool, Cheong Kwang-Ho, Kim Kyubo, Park Hae Jin, Park Younghee, Koh Hyeon Kang, Kim Byoung Hyuck, Kim Eunji, Kim Kyung Su, Choi Jin Hwa

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We aimed to evaluate the inter-clinician variability in the clinical target volume (CTV) for postoperative radiotherapy (PORT) for biliary tract cancer (BTC) including extrahepatic bile duct cancer (EBDC) and gallbladder cancer (GBC). Nine experienced radiation oncologists delineated PORT CTVs for distal EBDC (pT2N1), proximal EBDC (pT2bN1) and GBC (pT2bN1) patients. The expectation maximization algorithm for Simultaneous Truth and Performance Level Estimation (STAPLE) was used to quantify expert agreements. We generated volumes with a confidence level of 80% to compare the maximum distance to each CTV in six directions. The degree of agreement was moderate; overall kappa values were 0.573 for distal EBDC, 0.513 for proximal EBDC, and 0.511 for GBC. In the distal EBDC, a larger variation was noted in the right, post, and inferior direction. In the proximal EBDC, all borders except the right and left direction showed a larger variation. In the GBC, a larger variation was found in the anterior, posterior, and inferior direction. The posterior and inferior borders were the common area having discrepancies, associated with the insufficient coverage of the paraaortic node. A consensus guideline is needed to reduce inter-clinician variability in the CTVs and adequate coverage of regional lymph node area.

Для цитирования: Koo Taeryool, Cheong Kwang-Ho, Kim Kyubo, Park Hae Jin, Park Younghee, Koh Hyeon Kang, Kim Byoung Hyuck, Kim Eunji, Kim Kyung Su, Choi Jin Hwa. Variation in clinical target volume delineation in postoperative radiotherapy for biliary tract cancer.. PloS one. 2022. DOI: 10.1371/journal.pone.0273395.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.