MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11548-026-03790-1

Медицинская библиотека · International journal of computer assisted radiology and surgery · 2026

A U-Net Transformer for magnetic resonance elastography.

Zhong Weiheng, Urban Matthew W, Meidani Hadi

СтатьяПеревод в очереди

Аннотация

PURPOSE: Magnetic resonance elastography (MRE) is a critical non-invasive modality for quantifying tissue stiffness, but its clinical utility is limited by the high computational cost and noise sensitivity of traditional inversion techniques, such as algebraic Helmholtz inversion (AHI) and finite element methods (FEM). This study proposes a high-performance deep learning alternative to accelerate and stabilize MRE reconstruction.

METHODS

We developed an open-source, physics-based simulation framework that pairs realistic liver and tumor geometries from the LiTS dataset with clinically informed stiffness priors to generate a large-scale benchmark dataset. To improve reconstruction accuracy, we introduce the U-Net Transformer (UNT), a novel architecture that hybridizes the local inductive bias of convolutional neural networks with the global context-awareness of Transformers.

RESULTS

Numerical experiments indicate that data-driven training consistently outperforms physics-informed training in prediction accuracy. The proposed UNT architecture demonstrates significantly higher reconstruction accuracy than current state-of-the-art machine learning models. Additionally, we validated a physics-informed fine-tuning strategy that adapts the model to "sparse-data" clinical scenarios, enhancing patient-specific accuracy with minimal computational overhead.

CONCLUSION

The UNT architecture and the accompanying simulation framework establish a standardized foundation for AI-driven MRE inversion. By providing a rigorous performance baseline for neural operators, this work offers a validated pathway toward real-time, AI-assisted clinical decision support in radiological diagnostics.

Для цитирования: Zhong Weiheng, Urban Matthew W, Meidani Hadi. A U-Net Transformer for magnetic resonance elastography.. International journal of computer assisted radiology and surgery. 2026. DOI: 10.1007/s11548-026-03790-1.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.