Introduction of a Structured Reporting Protocol and Surgical Checklist for Rezum Water Vapor Therapy (VAPOR-SRP).
Аннотация
Background/
Objectives
Rezum water vapor therapy for benign prostatic obstruction lacks standardized documentation, complicating data comparison. This study evaluates the completeness of non-standardized Rezum operative reports and validates a novel Rezum-Structured Reporting Protocol (SRP) to enhance documentation quality.
Methods
Following the establishment of content validity, the SRP-which includes detailed diagrams for various prostatic urethral lengths (PUL) and intravesical prostatic protrusion (IPP) to document injection sites, along with a comprehensive 10-item checklist capturing factors that may influence outcomes-was retrospectively applied to 100 Rezum cases. Operative videos and non-standardized reports were analyzed and compared against the SRP. For criterion validity, inter-rater reliability was evaluated through a blinded review of 20 cases by three Rezum users and the protocol development panel, comparing checklist item ratings.
Results
Median number of injections was 4.0 (IQR: 2-6), injection density was 12.7 (IQR: 10-16.7) mL (PVOL)/injection, and injection interval was 0.7 (IQR: 0.5-1) cm (PUL)/injection. Variations in injection techniques were noted, including non-standard locations in 10% of cases and alternating injection sequences between lobes in 22%. Only 30% of reports detailed injection sites accurately. The intraclass coefficient for the rating of PUL was 0.94 (95% CI: 0.89-0.97). The Fleiss Kappa for MLE and IPP was 0.84 (95% CI: 0.66-1.02) and 0.85 (95% CI: 0.67-1.03), respectively. The agreement rate was 93% for bladder neck/urethra morphology and 100% for injection sequence. Kendall's W was 0.37 (p = 0.343) for the item of injection sites.
Conclusions
Variability in Rezum surgical techniques was observed, particularly in injection density, injection intervals, and precise injection locations, as well as in the structured information of non-SRP-standardized operative reports. Content validity of the SRP was achieved, leading to high inter-rater reliability in its application. The SRP promotes the standardization and completeness of Rezum data, thereby supporting improved, consistent, and high-quality Rezum documentation.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.