MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/978-3-031-32371-3_11

Медицинская библиотека · Advances in experimental medicine and biology · 2023

Enhanced Peripheral Chemoreflex Drive Is Associated with Cardiorespiratory Disorders in Mice with Coronary Heart Disease.

Bravo Liena, Pereyra Katherin V, Diaz Hugo S, Flores Mariajosé, Schwarz Karla G, Toledo Camilo, Díaz-Jara Esteban, González Leticia, Andia Marcelo E, Del Rio Rodrigo

СтатьяПеревод в очереди

Аннотация

Coronary heart disease (CHD) is a prevalent cardiovascular disease characterized by coronary artery blood flow reductions caused by lipid deposition and oxidation within the coronary arteries. Dyslipidemia is associated with local tissue damage by oxidative stress/inflammation and carotid bodies (CB) peripheral chemoreceptors are heavily modulated by both reactive oxygen species and pro-inflammatory molecules (i.e., cytokines). Despite this, it is not know whether CB-mediated chemoreflex drive may be affected in CHD. In the present study, we evaluated peripheral CB-mediated chemoreflex drive, cardiac autonomic function, and the incidence of breathing disorders in a murine model of CHD. Compared to age-matched control mice, CHD mice showed enhanced CB-chemoreflex drive (twofold increase in the hypoxic ventilatory response), cardiac sympathoexcitation, and irregular breathing disorders. Remarkably, all these were closely linked to the enhanced CB-mediated chemoreflex drive. Our results showed that mice with CHD displayed an enhanced CB chemoreflex, sympathoexcitation, and disordered breathing and suggest that CBs may be involved in chronic cardiorespiratory alterations in the setting of CHD.

Для цитирования: Bravo Liena, Pereyra Katherin V, Diaz Hugo S, Flores Mariajosé, Schwarz Karla G, Toledo Camilo, Díaz-Jara Esteban, González Leticia, Andia Marcelo E, Del Rio Rodrigo. Enhanced Peripheral Chemoreflex Drive Is Associated with Cardiorespiratory Disorders in Mice with Coronary Heart Disease.. Advances in experimental medicine and biology. 2023. DOI: 10.1007/978-3-031-32371-3_11.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.