MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.anl.2009.12.001

Медицинская библиотека · Auris, nasus, larynx · 2010

Balloon catheter assisted excision of benign cervical cyst.

Yoo Young Sam, Woo Hoon Young, Choi Jeong Hwan, Cho Kyoung Rai, Oh Young Taek, Heo Geon

СтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVES

Benign cystic masses that develop in the neck are easily excised with a wide skin incision. However, if the cyst is perforated and the contour of the cyst is not maintained during surgery, complete excision may be difficult. We developed a surgical method that can maintain the contour of a cyst and decrease the wound size with a balloon catheter.

METHODS

Two cases with a branchial cleft cyst (BCC) were removed using this method without recurrence. The surgical technique includes a skin incision above the cyst, and fine dissection to expose the cyst wall. Then a small tap incision was created on the cyst using a #11 blade and a #14 Fr. Foley catheter was inserted through the incision site and the balloon was inflated up to 4 cm(3) using normal saline. The fluid inner content was carefully removed keeping the intracystic balloon inflated. By pulling and releasing the catheter, the cyst was dissected carefully and excised.

RESULTS

Complete excision of the cyst was performed with the balloon catheter successfully. The final pathological diagnosis was BCC in the two cases.

CONCLUSIONS

The balloon-assisted technique was easy to perform and could be used for the excision of a benign cystic neck mass.

Для цитирования: Yoo Young Sam, Woo Hoon Young, Choi Jeong Hwan, Cho Kyoung Rai, Oh Young Taek, Heo Geon. Balloon catheter assisted excision of benign cervical cyst.. Auris, nasus, larynx. 2010. DOI: 10.1016/j.anl.2009.12.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.