DOI 10.1038/s41372-025-02461-4
Diagnostic accuracy of real‑time point-of-care tracheal ultrasonography for the confirmation of proper endotracheal tube placement in neonatal acute care settings: a systematic review and diagnostic test accuracy meta-analysis.
Аннотация
Accurate confirmation of endotracheal tube (ETT) placement is critical in neonatal resuscitation. This systematic review and meta-analysis assessed the diagnostic accuracy of point-of-care ultrasound (POCUS) for confirming ETT placement in neonates. We searched PubMed, Scopus, Web of Science, and Cochrane Library through May 2025. Eligible studies included neonates (<28 days) and compared POCUS with gold-standard confirmation (capnography, chest radiography, or direct laryngoscopy). Diagnostic performance was pooled using a bivariate random-effects model. Thirteen studies (930 neonates) met inclusion criteria. POCUS showed pooled sensitivity of 93% and specificity of 59%, with an area under the SROC curve of 92%. tracheal placement was confirmed in 99%, and esophageal misplacement detected in 4%. Subgroup analysis indicated higher accuracy by neonatologists and with linear transducers. POCUS offers a rapid, radiation-free method for confirming neonatal ETT placement. Broader implementation requires standardized techniques and operator training.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.