m+Medelevator.RU
← Поиск публикаций
Korean journal of radiology · 2023

Impact of Surveillance Mammography Intervals Less Than One Year on Performance Measures in Women With a Personal History of Breast Cancer.

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Janie M, Ichikawa Laura E, Wernli Karen J, Bowles Erin J A, Specht Jennifer M, Kerlikowske Karla, Miglioretti Diana L, Lowry Kathryn P, Tosteson Anna N A, Stout Natasha K, Houssami Nehmat, Onega Tracy, Buist Diana S M

Аннотация

OBJECTIVE: When multiple surveillance mammograms are performed within an annual interval, the current guidance for one-year follow-up to determine breast cancer status results in shared follow-up periods in which a single breast cancer diagnosis can be attributed to multiple preceding examinations, posing a challenge for standardized performance assessment. We assessed the impact of using follow-up periods that eliminate the artifactual inflation of second breast cancer diagnoses.

MATERIALS AND METHODS: We evaluated surveillance mammograms from 2007-2016 in women with treated breast cancer linked with tumor registry and pathology outcomes. Second breast cancers included ductal carcinoma in situ or invasive breast cancer diagnosed during one-year follow-up. The cancer detection rate, interval cancer rate, sensitivity, and specificity were compared using different follow-up periods: standard one-year follow-up per the American College of Radiology versus follow-up that was shortened at the next surveillance mammogram if less than one year (truncated follow-up). Performance measures were calculated overall and by indication (screening, evaluation for breast problem, and short interval follow-up).

RESULTS: Of 117971 surveillance mammograms, 20% (n = 23533) were followed by another surveillance mammogram within one year. Standard follow-up identified 1597 mammograms that were associated with second breast cancers. With truncated follow-up, the breast cancer status of 179 mammograms (11.2%) was revised, resulting in 1418 mammograms associated with unique second breast cancers. The interval cancer rate decreased with truncated versus standard follow-up (3.6 versus 4.9 per 1000 mammograms, respectively), with a difference (95% confidence interval [CI]) of -1.3 (-1.6, -1.1). The overall sensitivity increased to 70.4% from 63.7%, for the truncated versus standard follow-up, with a difference (95% CI) of 6.6% (5.6%, 7.7%). The specificity remained stable at 98.1%.

CONCLUSION: Truncated follow-up, if less than one year to the next surveillance mammogram, enabled second breast cancers to be associated with a single preceding mammogram and resulted in more accurate estimates of diagnostic performance for national benchmarks.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты