MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-023-07969-x

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023

The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis.

Ouyang Feng, Wu Qin, Chen Ye, Yin Mingxue, Liu Jie, Lv Lianjiang, Xu Zihe, Yuan Xiaoru, Zeng Xianjun

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Spinal arteriovenous fistulas (SAVF) was often neglected and misdiagnosed as acute transverse myelitis (ATM) due to its insidious onset and non-specific clinical symptoms. This study aims to investigate the differential diagnostic value of high-resolution T2-weighted volumetric sequence (3D sampling perfection with application-optimized contrasts using different flip-angle evolutions [SPACE]) in patients with SAVF and ATM.

METHODS

Retrospectively analyzed the clinical and radiological findings of 32 SDAVF patients and 32 ATM patients treated at our institutions from May 2018 to January 2023. They all underwent conventional spinal MRI and T2-SPACE examination, compared their performance in identifying lesions, to estimate the value of T2 SPACE sequence in the diagnosis of SAVF and ATM patients.

RESULTS

The clue of cauda equina area change (CEAC) in conventional MRI and T2-SPACE sequences is specific for the diagnosis of SAVF. The diagnostic model composed of perimedullary flow voids (PFV) and CEAC has good diagnostic performance (AUCMRI = 0.95; AUCSPACE = 0.935). Compared with conventional MRI, the T2-SPACE sequence has a higher detection rate, sensitivity, and negative predictive value for PFV and CEAC in SAVF patients, but lower specificity and positive predictive value. In T2-SPACE images, there are significant differences in the distribution range, quadrant, and maximum diameter of PFV vessels between SAVF and ATM patients. Moreover, T2-SPACE sequence can determine the site of fistula in most SAVF patients preferably, and the inter-rater agreement was good in the assessment of the fistula.

CONCLUSION

The CEAC is a new and useful clue for the diagnosis of thoracolumbar SAVF. And T2-SPACE sequence can more intuitively observe the lesions of SAVF, has good differential diagnostic value for SAVF and ATM patients.

Для цитирования: Ouyang Feng, Wu Qin, Chen Ye, Yin Mingxue, Liu Jie, Lv Lianjiang, Xu Zihe, Yuan Xiaoru, Zeng Xianjun. The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2023. DOI: 10.1007/s00586-023-07969-x.