m+Medelevator.RU
← Поиск публикаций
The Journal of arthroplasty · 2021

Survivorship, Clinical and Radiographic Outcomes of a Novel Cementless Metal-Backed Patella Design.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Grau Luis C, Ong Alvin C, Restrepo Santiago, Griffiths Sean Z, Hozack William J, Smith Eric B

Аннотация

BACKGROUND: Enhanced implant longevity through biological fixation is achievable using cementless total knee arthroplasty but concerns about patellar component failure have lingered because of prior experiences with older component designs. A new metal-backed patella (MBP) design was released which features a 3-dimensional printed porous titanium metal backing to improve biologic fixation potential and a unique compression molding technique to create a stronger interlock layer between the polyethylene and metal backing. Our study purpose was to determine the clinical and radiographic outcomes and survivorship of this novel cementless MBP.

METHODS: Our institutional registry identified 388 cementless MBP with minimum 2-year and 80 with minimum 5-year follow-up. Knee Injury and Osteoarthritis Outcome Score for Joint Replacement and 12-item Veterans RAND/Short Form Health Survey (VR/SF-12) scores were used to evaluate clinical outcomes. Aseptic loosening noted on radiographs as well as revision for any reason were the end points used to determine survivorship.

RESULTS: Improvement in the preoperative Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, VR/SF-12 physical health and mental health scores were all statistically significant at 2-year follow-up and the VR/SF-12 mental health score at 5-year follow-up. By radiologic criteria, biologic fixation of the patellar component was present in all except 1 case at 2 years (99.6%) and at 5 years (97.7%). Radiolucent lines were present in 15 cases (6.2%) at 2 years and in 6 cases (14%) at 5 years, but progressive increase in radiolucent lines was seen in only 4 cases. No component was revised for loosening; aseptic survivorship was 100%.

CONCLUSION: This 3-dimensional printed cementless patellar component shows excellent survivorship at 2-year and 5-year follow-up. We are hopeful about the long-term durability of this implant.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты