MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1510/icvts.2007.172007

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2008

Human parietal pleura present electrophysiology variations according to location in pleural cavity.

Kouritas Vassilios K, Hatzoglou Chrisi, Foroulis Christophoros N, Gourgoulianis Konstantinos I

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

The aim of the study was to investigate if human pleura from different anatomical locations presents electrophysiology differences. Specimens were stripped over the 2nd-5th rib (cranial), 8th-10th rib (caudal), and mediastinum during open surgery and were mounted between Ussing chambers. Amiloride and ouabain were added towards mesothelial surface and trans-mesothelial potential difference (PD) was measured after 1, 5, 10 and 20 min. Trans-membrane resistance (R) was calculated from Ohm's law. R increased after amiloride addition, for cranial (net increase of 0.40 Omega x cm(2)) and caudal (1.16 Omega x cm(2)) pleural pieces. Mediastinal pleura R remained unchanged (0.09 Omega x cm(2)). R increase was higher for caudal than cranial (P=0.029) or mediastinal tissues (P=0.002). R increased after ouabain addition for caudal (1.35 Omega x cm(2)) and cranial (0.56 Omega x cm(2)) pleural pieces. Mediastinal pleural tissue did not respond (0.20 Omega x cm(2)). Caudally located pleura responded greater than cranial (P=0.043) or mediastinal (P=0.003) pleural tissues. Human pleura shows electrophysiology differences according to the location within the pleural cavity. Surgeons may waste mediastinal pleura when needed but should leave intact caudal parietal pleura, which seems to be electrophysiologically the most important part of the pleural cavity.

Для цитирования: Kouritas Vassilios K, Hatzoglou Chrisi, Foroulis Christophoros N, Gourgoulianis Konstantinos I. Human parietal pleura present electrophysiology variations according to location in pleural cavity.. Interactive cardiovascular and thoracic surgery. 2008. DOI: 10.1510/icvts.2007.172007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.