m+Medelevator.RU
← Поиск публикаций
Ophthalmology science · 2025

Automated Feature Segmentation of Ultra-Widefield OCT Images.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Jackson John D, Woodward Mani K, Sutter David A, Coyner Aaron S, Wang Carol X, Ostmo Susan R, Chiang Michael F, Jia Yali, Huang David, Jian Yifan, Campbell J Peter, Young Benjamin K

Аннотация

OBJECTIVE OR PURPOSE: To develop a lightweight neural network for automated cross-sectional and en face segmentation of ultra-widefield (UWF) OCT images acquired for retinopathy of prematurity screening.

DESIGN: Cross-sectional study.

SUBJECTS: Twenty-five infants with a birth weight <1500 g or gestational age <31 weeks were scanned using a portable, handheld, swept-source UWF-OCT device.

METHODS INTERVENTION OR TESTING: For cross-sectional B-scans, 3040 B-scans from 5 OCT volumetric scans obtained from 5 patients were segmented by 2 graders for the choroid and retina using custom-built tools in the Napari image viewer. Using these segmentations, a u-net with an EfficientNet-B0 backbone was trained in combination with task-specific augmentations to perform automated segmentation of the retina and choroid data with varying levels of image processing applied. For en face scans, 40 en face images from 20 unique patients were manually segmented by a single grader for retinal vessels. Using these segmentations, a u-net with an EfficientNet-B0 backbone was trained. Validation for both B-scans and en face images was performed using fivefold cross-validation. The fivefold cross-validation metrics were then compared with the metrics obtained by comparing grader segmentations.

MAIN OUTCOME MEASURES: The Dice similarity coefficient (DSC) was used to assess B-scan and en face segmentations.

RESULTS: The retinal and choroidal b-scan segmentations produced a DSC ± standard deviation of 0.925 ± 0.021 and 0.797 ± 0.062, respectively, averaged across the fivefolds. The en face vasculature segmentation produced a DSC ± standard deviation of 0.625 ± 0.0450.

CONCLUSIONS: Using u-net convolutional neural networks trained with task-specific augmentations, we developed en face and cross-sectional segmentations for UWF-OCT images, which will facilitate automated quantitative analysis with this novel modality.

FINANCIAL DISCLOSURES: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты