MedElevator Войти в исследования
← Поиск публикаций

DOI 10.47391/jpma-bagh-16-68

Медицинская библиотека · JPMA. The Journal of the Pakistan Medical Association · 2024

An efficacy of protection the organs at risks comparison between the intensitymodulated radiotherapy therapy (IMRT) and the three-dimensional conformal radiotherapy (3DCRT).

Abd Ali Khaleel Abd Al-Taj, Abdullah Siham Sabah, Al-Bayaty Sabbar Shukri, Abdulbaqi Abdulrahman Mohammed, Ali Alazawy Nabaa Mohammad

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To compare the efficiency of three-dimensional conformal radiotherapy and intensity-modulated radiation therapy techniques.

METHOD: The cross-sectional study was conducted from February to August 2021 at Al-Amal National Hospital, Baghdad, Iraq, and comprised patients aged 19-45 years with cancerous head and neck tumours of size 2-7cm. All the patients underwent magnetic resonance imaging or computed tomography simulation scans. Treatment planning techniques used for each patient were three-dimensional conformal radiotherapy and intensitymodulated radiotherapy. After evaluating patterns, a better plan and treatment with an X-ray beam was chosen. Data was analysed using SPSS 24.

RESULTS

The study involved thirty participants, with 17(57%) females and 13(43%) males, aged 19-45, and 28 patients having chemotherapy. Six out of thirty had craniotomy surgery. The intensity-modulated radiation therapy had a safer radiation dose than the three-dimensional conformal radiotherapy for spinal cord (p=0.3203), brain stem (p= 0.17924), right parotid gland (p=0.8556) and left parotid gland (p=0.2193). The three-dimensional conformal radiotherapy protected the organs better than intensity-modulated radiation therapy for left optic nerve (p=0.1227), right optic nerve (p=0.0032), left eye (p=0.3859), right eye (p=0.1189), left lens (p=0.0004), right lens (p=0.0001), optic chiasm (p=0.0320) and pituitary gland (p=0.9162).

CONCLUSIONS

The intensity-modulated radiation therapy technique protected the spinal cord, brain stem, and right and left parotid glands. The three-dimensional conformal radiotherapy was safe for left and right optic nerves, left and right eyes, left and right lenses, optic chiasm and pituitary glands.

Другие публикации по теме

Radiotherapy, ConformalRadiotherapy, Intensity-ModulatedCross-Sectional StudiesOrgans at Risk
Для цитирования: Abd Ali Khaleel Abd Al-Taj, Abdullah Siham Sabah, Al-Bayaty Sabbar Shukri, Abdulbaqi Abdulrahman Mohammed, Ali Alazawy Nabaa Mohammad. An efficacy of protection the organs at risks comparison between the intensitymodulated radiotherapy therapy (IMRT) and the three-dimensional conformal radiotherapy (3DCRT).. JPMA. The Journal of the Pakistan Medical Association. 2024. DOI: 10.47391/jpma-bagh-16-68.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.