MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmig.2017.02.018

Медицинская библиотека · Journal of minimally invasive gynecology · 2017

Robotic-Assisted Laparoscopic Trachelectomy: A Standard Technique.

Mahmoud Mohamad S

Клинический случайСтатьяVideo-Audio MediaПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To describe a standard reproducible technique for simple robotic- assisted laparoscopic trachelectomy.

DESIGN

Step-by-step demonstration of the technique using videos and pictures (Canadian Task Force classification level 3).

SETTING

The incidence of trachelectomy after supracervical hysterectomy has been increasing, given the popularity of supracervical hysterectomy. The most common indication for trachelectomy is symptomatic cyclic bleeding. Trachelectomy can be performed vaginally as well as laparoscopically with or without robotic assistance. This video demonstrates a standard reproducible technique for robotic-assisted trachelectomy in 2 women who underwent previous supracervical hysterectomy with a retained cervix.

INTERVENTIONS: Robotic-assisted laparoscopic trachelectomy using a standard technique is demonstrated in 2 different examples. The steps include opening the vesicocervical peritoneum, creating a bladder flap and pushing the bladder down beyond the vaginal cuff, opening the remnant of the broad ligament and delineating the course of cervical branch of the uterine artery and ureter bilaterally, inserting a uterine manipulator with a colpotomizer under vision, performing desiccation of the cervical branches of the uterine artery, and performing colpotomy and closure of the vaginal cuff.

CONCLUSION

Robotic-assisted laparoscopic trachelectomy is a safe and simple procedure that should be part of all general gynecologists' armamentarium. The described technique is reproducible and efficient and can be adopted for all cases requiring simple trachelectomy.

Для цитирования: Mahmoud Mohamad S. Robotic-Assisted Laparoscopic Trachelectomy: A Standard Technique.. Journal of minimally invasive gynecology. 2017. DOI: 10.1016/j.jmig.2017.02.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.