MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/qims-20-868

Медицинская библиотека · Quantitative imaging in medicine and surgery · 2021

Automatic 3D adaptive vessel segmentation based on linear relationship between intensity and complex-decorrelation in optical coherence tomography angiography.

Zhang Yiming, Li Huakun, Cao Tongtong, Chen Ruixiang, Qiu Haixia, Gu Ying, Li Peng

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Vascular quantitative metrics have been widely used in the preclinical studies and clinical applications (e.g., the diagnosis and treatment of port wine stain, PWS), which require accurate vessel segmentation. An automatic 3D adaptive vessel segmentation is in need for a reproducible and objective quantification of the optical coherence tomography angiography (OCTA) image.

METHODS

Human skin imaging was performed with a lab-built optical coherence tomography (OCT) system. Rather than separately applying the conventional 2-step (intensity and binarization) thresholding in the decorrelation-contrast OCTA, we proposed a 3D adaptive threshold using the linear relationship between the local intensity and complex-decorrelation which was termed as inverse SNR-decorrelation (ID) threshold. Furthermore, the ID threshold was automatically determined by defining a binary image similarity (BISIM) index as the feedback and searching the ID threshold with the minimal BISIM value. The proposed ID-BISIM threshold was applied to the acquired OCTA skin images for further vessel quantification.

RESULTS

The proposed ID-BISIM threshold enabled a 3D adaptive binarization and presented superior sensitivity and specificity in vessel segmentation over conventional 2-step thresholding method in the decorrelation-contrast OCTA and a 37-65% improvement of the Youden's index in human skin experiments. The 3D binarization enabled a depth-resolved vessel skeleton and enhanced the differentiation of the overlapping vessels in the depth direction. Using ID-BISIM, the quantitative OCTA image presented a significant increase of vessel diameter index (P=0.0015) and vessel area density (VAD) (P=0.0485) as well as a significant decrease of vessel complexity index (VCI) (P=0.0094) in PWS lesion skin compared with normal skin.

CONCLUSIONS

The proposed ID-BISIM method enables an automatic 3D adaptive vessel segmentation with enhanced performance in quantitative OCTA. The vascular quantitative metrics would be a useful tool for improving the diagnosis and the treatment of PWS.

Для цитирования: Zhang Yiming, Li Huakun, Cao Tongtong, Chen Ruixiang, Qiu Haixia, Gu Ying, Li Peng. Automatic 3D adaptive vessel segmentation based on linear relationship between intensity and complex-decorrelation in optical coherence tomography angiography.. Quantitative imaging in medicine and surgery. 2021. DOI: 10.21037/qims-20-868.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.