DOI 10.1053/j.jvca.2022.12.025
Spinal Cord Infarction With Prolonged Femoral Venoarterial Extracorporeal Membrane Oxygenation.
Аннотация
OBJECTIVES
There have been sporadic reports of ischemic spinal cord injury (SCI) during venoarterial extracorporeal membrane oxygenation (VA-ECMO) support. The authors observed a troubling pattern of this catastrophic complication and evaluated the potential mechanisms of SCI related to ECMO.
DESIGN
This study was a case series.
SETTING
This study was performed at a single institution in a University setting.
PARTICIPANTS
Patients requiring prolonged VA-ECMO were included.
INTERVENTIONS: No interventions were done. This was an observational study.
MEASUREMENTS AND MAIN
RESULTS
Four hypotheses of etiology were considered: (1) hypercoagulable state/thromboembolism, (2) regional hypoxia/hypocarbia, (3) hyperperfusion and spinal cord edema, and (4) mechanical coverage of spinal arteries. The SCI involved the lower thoracic (T7-T12 level) spinal cord to the cauda equina in all patients. Seven out of 132 (5.3%) patients with prolonged VA-ECMO support developed SCI. The median time from ECMO cannulation to SCI was 7 (range: 6-17) days.There was no evidence of embolic SCI or extended regional hypoxia or hypocarbia. A unilateral, internal iliac artery was covered by the arterial cannula in 6/7 86%) patients, but flow into the internal iliac was demonstrated on imaging in all available patients. The median total flow (ECMO + intrinsic cardiac output) was 8.5 L/min (LPM), and indexed flow was 4.1 LPM/m2. The median central venous oxygen saturation was 88%, and intracranial pressure was measured at 30 mmHg in one patient, suggestive of hyperperfusion and spinal cord edema.
CONCLUSIONS
An SCI is a serious complication of extended peripheral VA-ECMO support. Its etiology remains uncertain, but the authors' preliminary data suggested that spinal cord edema from hyperperfusion or venous congestion could contribute.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.