MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/advs.77162

Медицинская библиотека · Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026

Self-Amplified Activatable Fluorescent Probe for Early Diagnosis of Acute Kidney Injury and High-Throughput Screening of Natural Protectants.

Chen Yahui, Liu Meihong, Ding Mengchao, Liu Ye, Zhu Chuanxu, Gong Mingye, Huang Zhixuan, Zhang Yi, Xue Wei, Yuan Youyong, Wang Kewei

СтатьяПеревод в очереди

Аннотация

Early diagnosis of acute kidney injury (AKI) and identification of effective therapeutics remain significant clinical challenges. Herein, we developed an activatable near-infrared fluorescent nanoprobe (denoted PS-QRC) by encapsulating a self-amplifying fluorescent sensor (QRCy) within kidney-targetable L-serine-functionalized ultrasmall poly(amidoamine) (PAMAM-Ser) dendrimers. Upon activation by reactive oxygen species (ROS), QRCy undergoes self-fragmentation, releasing four fluorophores to amplify the fluorescence signal, affording an ultra-low detection limit of 81 nM for hydrogen peroxide. The L-serine modification enables specific binding of PS-QRC to kidney injury molecule-1 (KIM-1), which is overexpressed in injured renal tubules, thereby promoting renal accumulation and reducing background interference. Impressively, PS-QRC allows noninvasive real-time imaging of cisplatin-induced AKI in mice as early as 12 h, significantly earlier than conventional serum biochemical and histopathological analyses. Furthermore, a high-throughput screening platform was established using this nanoprobe to evaluate natural products, from which chrysin was identified as a promising renoprotective agent. Chrysin demonstrated both in vitro and in vivo renoprotective effects, with efficacy comparable to the established antioxidant N-acetylcysteine. Moreover, PS-QRC enabled quantitative monitoring of chrysin's dose-dependent therapeutic response. Overall, this integrated probe provides a sensitive and reliable tool for early AKI diagnosis and the high-throughput discovery of novel renoprotective drugs.

Для цитирования: Chen Yahui, Liu Meihong, Ding Mengchao, Liu Ye, Zhu Chuanxu, Gong Mingye, Huang Zhixuan, Zhang Yi, Xue Wei, Yuan Youyong, Wang Kewei. Self-Amplified Activatable Fluorescent Probe for Early Diagnosis of Acute Kidney Injury and High-Throughput Screening of Natural Protectants.. Advanced science (Weinheim, Baden-Wurttemberg, Germany). 2026. DOI: 10.1002/advs.77162.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.