MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acssensors.6c02385

Медицинская библиотека · ACS sensors · 2026

Transdermal Creatinine Sensing in Live Animals with an Integrated Electrochemical Microneedle Patch.

Li Yang, Liu Chang, Yang Zhanqun, Papakonstantinou Pagona, Chen Long, Li Meixian

СтатьяПеревод в очереди

Аннотация

Over 700 million people worldwide are estimated to suffer from chronic kidney disease (CKD), and creatinine is a critical biomarker for diagnosing and managing CKD. However, conventional detection relies on invasive blood sampling and time-consuming protocols and is susceptible to interference from endogenous substances and drugs. This highlights an urgent demand for convenient, non-invasive, and accurate monitoring strategies. This study presents a wearable electrochemical microneedle (MN) patch for minimally invasive and enzyme-free creatinine detection in transdermal interstitial fluid (ISF). Solid polycarbonate MNs are coated with conductive poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate). Copper ions (Cu2+) are immobilized on the surface through immersion treatment via coordination and electrostatic interactions, and a Nafion film is finally deposited to enhance stability and anti-interference ability. Quantitative detection is based on the peak current generated from the electrochemical oxidation of in situ formed Cu0 to Cu+, which subsequently undergoes specific coordination with creatinine. The patch exhibits a linear detection range of 5.00-300 μM for creatinine with a minimum detectable concentration of 1.00 μM. Benefiting from the strong coordination effect and permselectivity of Nafion, the patch shows high stability, excellent anti-interference ability, and reliable sensing performance. Integrated with a handheld potentiostat, this compact, lightweight, and low-cost sensor achieves real-time and accurate creatinine sensing within 90 s in ISF of live rabbit models, showing great promise for long-term home-based CKD management.

Для цитирования: Li Yang, Liu Chang, Yang Zhanqun, Papakonstantinou Pagona, Chen Long, Li Meixian. Transdermal Creatinine Sensing in Live Animals with an Integrated Electrochemical Microneedle Patch.. ACS sensors. 2026. DOI: 10.1021/acssensors.6c02385.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.