m+Medelevator.RU
← Поиск публикаций
Journal of the American Veterinary Medical Association · 2026

Caudal vena cava-to-aorta ratio in hemodynamically stable and unstable client-owned rabbits.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lashlee Taylor, Tollefson Christopher R, Pigott Armi M, Thielen Lauren, De Silva Margherita, Di Girolamo Nicola

Аннотация

OBJECTIVE: To determine the feasibility of measuring caudal vena cava (CVC) and aorta size in non-contrast-enhanced CT scans of rabbits, variations in size and circularity depending on anatomical location, factors and conditions affecting the CVC-to-aorta (CVC:Ao) ratios, and changes of CVC:Ao ratios in hemodynamically unstable rabbits.

METHODS: This retrospective cohort study included consecutive client-owned rabbits that presented to the Cornell University Hospital for Animals between June 2022 and October 2024 and received an abdominal CT. Forty-nine CT scans from 46 individual rabbits were included. The CVC:Ao ratio was determined similarly to dogs. Hemodynamically instability was assessed by 2 independent blinded investigators.

RESULTS: 100% (95% CI, 92.8% to 100%) and 87.8% (95% CI, 75.2% to 95.4%) of the thoracic and abdominal CVC:Ao ratios, respectively, were measurable. Several factors were associated with abdominal and thoracic CVC:Ao ratios and their difference, including a higher difference between abdominal and thoracic ratio in rabbits with intestinal obstruction. The abdominal CVC:Ao ratio and the difference between abdominal and thoracic CVC:Ao ratio were significant predictors of hemodynamic instability, with a 6-fold and 8-fold increase in the odds of hemodynamic instability for every additional unit of these ratios and an area under the curve of 0.73 (95% CI, 0.56 to 0.91) and of 0.79 (95% CI, 0.64 to 0.93).

CONCLUSIONS: In diseased rabbits, the aorta and CVC are larger and less circular in the thorax than in the abdomen. In hemodynamic unstable rabbits, the thoracic CVC:Ao ratio decreased while the abdominal CVC:Ao ratio increased, likely owing to gastric compression on the vena cava.

CLINICAL RELEVANCE: CVC:Ao ratios can be used as significant predictors of hemodynamic instability in diseased rabbits.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты