m+Medelevator.RU
← Поиск публикаций
JACC. Advances · 2025

Human Epididymis Protein 4 in Transcatheter Aortic Valve Implantation: Diagnostic and Prognostic Value.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Giuliani Carlos, Zanuttini Antonela, Nuche Jorge, Farjat Pasos Julio I, Bernard Jérémy, Lionel Tastet, Jacob Simon, Abu-Alhayja'a Rami, Beaudoin Jonathan, Côté Nancy, DeLarochellière Robert, Paradis Jean-Michel, Clavel Marie-Annick, Arsenault Benoit J, Rodés-Cabau Josep, Pibarot Philippe, Hecht Sébastien

Аннотация

BACKGROUND: The utility of the human epididymis protein 4 (HE4) in patients undergoing transcatheter aortic valve implantation (TAVI) has not been established yet.

OBJECTIVES: The present study aimed at examining the prognostic value of HE4 in patients undergoing TAVI.

METHODS: In this prospective study, the prognostic value of HE4 to predict adverse clinical events was evaluated in 362 patients who underwent TAVI. The association between HE4 and diffuse myocardial fibrosis was also assessed using T1 mapping on cardiac magnetic resonance in a subgroup of 43 patients.

RESULTS: During a median follow-up of 2.5 (IQR: 1.9-3.2) years, 34/362 (9.4%) patients were rehospitalized for heart failure, 99/362 (27.3%) died, and 113/362 (31.2%) met the composite endpoint of rehospitalization for heart failure or all-cause mortality. In multivariable Cox regression analyses, patients with higher HE4 serum levels (ie, HE4 ≥130 pmol/L) vs lower serum levels (ie, HE4 <130 pmol/L) had increased risk of all-cause mortality (adjusted HR: 3.26 [95% CI: 2.04-5.20], P < 0.001), and of the composite endpoint (adjusted HR: 2.48 [95% CI: 1.64-3.74], P < 0.001) following TAVI, respectively. Patients with higher HE4 serum levels had higher median native T1 mapping values (1,278 [95% CI: 1,239-1,280] ms vs 1,352 [95% CI: 1,303-1,376] ms, P < 0.001) at 1 to 3 months following the procedure.

CONCLUSIONS: Elevated HE4 serum levels are associated with diffuse myocardial fibrosis and increased risk of adverse clinical events following TAVI. This promising blood biomarker may be helpful to enhance risk stratification in patients undergoing TAVI.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты