m+Medelevator.RU
← Поиск публикаций
BMJ open gastroenterology · 2025

Provocative tests of anal sphincter function correlate with symptoms and subtypes of faecal incontinence.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

O'Connor Alexander, Liao Donghua, Davenport Matthew, Sharma Abhiram, Vasant Dipesh H, Klarskov Niels, Drewes Asbjørn Mohr, Kiff Edward, McLaughlin John, Telford Karen

Аннотация

OBJECTIVES: High-resolution anorectal manometry (HRAM) is the established investigation in faecal incontinence (FI). However, provocative tests (functional lumen imaging probe (FLIP) and anal acoustic reflectometry (AAR)) have been proposed as alternatives. This study uniquely explores all three methods in correlation with FI symptoms and subtypes.

METHODS: This was a prospective observational study of patients with FI attending a tertiary pelvic floor unit between August 2022 and January 2024. Patients underwent HRAM, FLIP and AAR with the order randomised. FI severity was assessed with the Vaizey score and quality-of-life with the Manchester Health Questionnaire.

RESULTS: 40 patients (39 women, median age: 62 (range: 38-85)) were recruited with 27 (67.5%) reporting urge FI, 8 (20%) mixed and 5 (12.5%) passive incontinence. FLIP squeeze measurements correlated with the Vaizey score, including incremental squeeze pressure at 40 mL (rs=-0.412; p=0.008) and 50 mL (rs=-0.414; p=0.009) and the pressure-diameter volume loop at 50 mL (rs=-0.402; p=0.011). Incremental squeeze opening pressure with AAR correlated with the Vaizey score (rs=-0.339; p=0.032). There was no correlation between symptom severity and HRAM parameters, or any parameter and quality-of-life scores. Resting parameters with all three modalities were lower in passive FI: mean resting pressure (HRAM; p=0.010), yield pressure (FLIP; p=0.031) and opening pressure (AAR; p=0.006). With FLIP, there was a trend towards reduced squeeze function in the urge group (pressure-diameter volume loop at 50 mL; p=0.295).

CONCLUSIONS: FLIP and AAR correlate better with FI symptoms compared with HRAM. Therefore, these provocative tests could be used to guide the management of FI in prospective studies.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты