MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2026.05.015

Медицинская библиотека · American journal of ophthalmology · 2026

Opacity Detection on Optical Coherence Tomography Based on an Incidence-Angle and Depth-Dependent Model of Corneal Reflectance.

Assaf Jad F, Yazbeck Hady, Sims Deion, Hong Jiachi, Liu Chun-Fu, Gunes Irem, Li Yan, Huang David

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To develop and validate an automated corneal opacity detection algorithm for optical coherence tomography (OCT) images, utilizing an incidence-angle- and depth-dependent model of corneal reflectance.

DESIGN

Retrospective, cross-sectional diagnostic accuracy study.

SUBJECTS: Training used 95 healthy eyes from 49 volunteers. Testing included 50 eyes from 42 patients with corneal opacities and 35 healthy eyes from 35 volunteers.

METHODS

Normal-eye OCT scans were used to model normative incidence-angle-dependent reflectance across corneal layers. The algorithm detected pixels above the normal reflectance range using model-based thresholds, binned percentile analysis, and morphological operations. Eye-level performance was evaluated against slit-lamp examination as clinical ground truth and compared with 5 trained physician annotators. Pixel-level agreement with consensus annotations (≥3 of 5 annotators) was assessed with Dice similarity coefficient.

MAIN OUTCOME MEASURES: Eye-level accuracy, F1-score, sensitivity, and specificity; pixel-level Dice similarity coefficient and segmented-area agreement versus consensus annotations.

RESULTS

At the eye level, the algorithm achieved accuracy of 0.93, F1-score of 0.94, sensitivity of 0.96, and specificity of 0.89. Human annotators had a mean accuracy of 0.83 ± 0.06, F1-score of 0.85 ± 0.04, sensitivity of 0.84 ± 0.09, and specificity of 0.80 ± 0.27. At the pixel level, mean Dice similarity coefficient versus consensus was 0.58 for the algorithm and 0.71 ± 0.05 for annotators. The algorithm's total segmented opacity area was close to the consensus pixel count (98% of consensus).

CONCLUSION

An algorithm that incorporates incidence angle and depth-specific reflectance thresholds detects and segments corneal opacities. It demonstrated favorable accuracy at the eye level and produced quantitative opacity maps on OCT.

Для цитирования: Assaf Jad F, Yazbeck Hady, Sims Deion, Hong Jiachi, Liu Chun-Fu, Gunes Irem, Li Yan, Huang David. Opacity Detection on Optical Coherence Tomography Based on an Incidence-Angle and Depth-Dependent Model of Corneal Reflectance.. American journal of ophthalmology. 2026. DOI: 10.1016/j.ajo.2026.05.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.