Morphological and Biomechanical Characterization of Amniotic Membranes Across Species: Equine, Canine, Porcine, Ovine, and Human Samples-A Pilot Study.

Petersen Michelle Becker, Seibel Maiara Poersch, Freitas Eduarda Correa, Locatelli Claudete Inês, Formenton Ana Bárbara Krummenauer, Vassoler Jakson Manfredini, Kwitko Sérgio, Marinho Diane Ruschel, Pigatto João Antonio Tadeu

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

The use of amniotic membrane (AM) has become well established in the treatment of ocular surface disorders in both humans and animals. However, comparative studies of AM from different species remain scarce.

OBJECTIVE

To compare the thickness and biomechanical properties of equine, canine, porcine, and ovine AMs with those of human AM.

METHODS

Placentas were collected, and AMs were manually separated from the chorion. All AM samples were cryopreserved in a 1:1 solution of Dulbecco's Modified Eagle's Medium (DMEM) and glycerin at -80°C for 60 days. After thawing, samples underwent thickness, histological, and biomechanical analyses.

RESULTS

Porcine and canine AMs had an average thickness of 0.054 mm, while ovine AM averaged 0.017 mm. Equine and human AMs had average thicknesses of 0.070 and 0.068 mm, respectively. The key mechanical properties evaluated were maximum tensile force (in Newtons) and stiffness (N/mm), derived from the force-displacement curve. Equine AM exhibited the highest mean maximum tensile force (5.21 N), followed by human (2.17 N), ovine (1.35 N), canine (1.34 N), and porcine (0.52 N). Equine AM also demonstrated the highest mean stiffness (0.91 N/mm), followed by human (0.51 N/mm), ovine (0.46 N/mm), canine (0.27 N/mm), and porcine (0.15 N/mm).

CONCLUSION

Equine AM closely resembles human AM in terms of thickness and mechanical behavior. Moreover, equine AM demonstrated superior biomechanical performance, suggesting its potential as a robust alternative biomaterial for ocular surface reconstruction.

Для цитирования: Petersen Michelle Becker, Seibel Maiara Poersch, Freitas Eduarda Correa, Locatelli Claudete Inês, Formenton Ana Bárbara Krummenauer, Vassoler Jakson Manfredini, Kwitko Sérgio, Marinho Diane Ruschel, Pigatto João Antonio Tadeu. Morphological and Biomechanical Characterization of Amniotic Membranes Across Species: Equine, Canine, Porcine, Ovine, and Human Samples-A Pilot Study.. Veterinary ophthalmology. 2026. DOI: 10.1111/vop.70236.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.