MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/japplphysiol.01068.2014

Медицинская библиотека · Journal of applied physiology (Bethesda, Md. : 1985) · 2015

Observation of cardiogenic flow oscillations in healthy subjects with hyperpolarized 3He MRI.

Collier Guilhem J, Marshall Helen, Rao Madhwesha, Stewart Neil J, Capener David, Wild Jim M

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Recently, dynamic MRI of hyperpolarized (3)He during inhalation revealed an alternation of the image intensity between left and right lungs with a cardiac origin (Sun Y, Butler JP, Ferrigno M, Albert MS, Loring SH. Respir Physiol Neurobiol 185: 468-471, 2013). This effect is investigated further using dynamic and phase-contrast flow MRI with inhaled (3)He during slow inhalations (flow rate ∼100 ml/s) to elucidate airflow dynamics in the main lobes in six healthy subjects. The ventilation MR signal and gas inflow in the left lower lobe (LLL) of the lungs were found to oscillate clearly at the cardiac frequency in all subjects, whereas the MR signals in the other parts of the lungs had a similar oscillatory behavior but were smaller in magnitude and in anti-phase to the signal in the left lower lung. The airflow in the main bronchi showed periodic oscillations at the frequency of the cardiac cycle. In four of the subjects, backflows were observed for a short period of time of the cardiac cycle, demonstrating a pendelluft effect at the carina bifurcation between the left and right lungs. Additional (1)H structural MR images of the lung volume and synchronized ECG recording revealed that maximum inspiratory flow rates in the LLL of the lungs occurred during systole when the corresponding left lung volume increased, whereas the opposite effect was observed during diastole, with gas flow redirected to the other parts of the lung. In conclusion, cardiogenic flow oscillations have a significant effect on regional gas flow and distribution within the lungs.

Для цитирования: Collier Guilhem J, Marshall Helen, Rao Madhwesha, Stewart Neil J, Capener David, Wild Jim M. Observation of cardiogenic flow oscillations in healthy subjects with hyperpolarized 3He MRI.. Journal of applied physiology (Bethesda, Md. : 1985). 2015. DOI: 10.1152/japplphysiol.01068.2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.